BLDC Insulation Classes

2026-05-28

Insulation Classes and Dielectric Strength

Standard Reference: GB/T 755 / IEC 60034-18

1. Thermal Insulation Classes

The "Insulation Class" defines the maximum temperature a motor's winding insulation system can withstand before it begins to degrade rapidly. In the BLDC industry, Class F and Class H are the most common standards.

Insulation Class Max Permissible Temp (Tmax​) Max Temp Rise (ΔT)
Class B $130^{\circ}\text{C}$ $80\text{K}$
Class F $155^{\circ}\text{C}$ $105\text{K}$
Class H $180^{\circ}\text{C}$ $125\text{K}$

Crucial Rule: Operating a motor $10^{\circ}\text{C}$ above its rated insulation temperature can reduce the insulation life by approximately 50%.

2. Dielectric Strength Test (Hi-Pot Test)

To ensure the safety of the motor system, national standards require a Dielectric Strength Test (also known as a High Potential or Hi-Pot test). This test verifies that the insulation between the windings and the motor frame is sufficient.

  • Standard Test Voltage: For motors with a rated voltage $U_N$, the test voltage is typically calculated as:

    $$U_{test} = 2 \times U_N + 1000\text{V}$$
  • Test Duration: 60 seconds (Routine test) or 1 second (Production line test at 120% voltage).

  • Pass Criteria: No breakdown or flashover should occur during the test.

3. Insulation Resistance (IR)

Before performing the Hi-Pot test, the Insulation Resistance must be measured using a Megohmmeter (typically at 500V DC).

  • Standard Requirement: The resistance should generally be $\ge 100\text{M}\Omega$ under cold conditions.

  • Correction: If measured at high temperatures, the resistance must be corrected to a reference temperature of $40^{\circ}\text{C}$.

4. Protection Against Thermal Overload

Standards require that BLDC motors, especially those in continuous operation (S1), must be equipped with thermal protection devices (e.g., PTC thermistors or KTY sensors) embedded in the windings if they are at risk of exceeding the insulation temperature limits.

5. Visual Representation (Instruction for Website Layout)

[Image Placement: Insulation Layers & Testing]

  • What to show: A technical illustration consisting of two parts:

    1. Left side: A cross-section of a motor stator slot showing the "Slot Liner", "Wire Enamel", and "Impregnating Resin" with their respective thermal class labels.

    2. Right side: A schematic of a "Hi-Pot Tester" connected to the motor windings and the ground frame, showing the safety insulation barrier.

  • Key Labels: "Phase-to-Phase Insulation", "Phase-to-Ground Insulation", "Voltage Breakdown Barrier".

Ref Document: Rotating electrical machines — Rating and performance (GB/T 755-2019).