BLDC Rated Parameters and Technical Characteristics
Brushless Motor Standards & Testing

BLDC Rated Parameters and Technical Characteristics

2026-05-26

Rated Parameters and Technical Characteristics

Standard Reference: GB/T 21418-2008 / GB/T 755-2019

1. Standard Rated Parameters (The Nameplate Requirements)

According to GB/T 755, every compliant brushless DC motor must have a permanently fixed nameplate clearly displaying its standard rating. The core parameters include:

  • Rated Power ($P_N$): The mechanical power delivered at the shaft under continuous standard duty, measured in Watts (W) or Kilowatts (kW).

  • Rated Voltage ($U_N$): The nominal DC input voltage supplied to the motor controller.

  • Rated Speed ($n_N$): The rotor speed when the motor operates at rated voltage and rated power, measured in revolutions per minute (r/min or RPM).

  • Rated Torque ($T_N$): The continuous torque output at rated speed, calculated based on power and speed:

    $$T_N = 9550 \times \frac{P_N}{n_N}$$

2. Torque-Speed Characteristics (BLDC Standard Curve)

Technical standards define specific operating regions for a BLDC motor system:

  1. Continuous Operating Region: The zone where the motor can run indefinitely without overheating (bounded by rated torque).

  2. Intermittent/Overload Region: The zone where the motor can operate for short durations (e.g., during startup or acceleration) before reaching thermal limits.

3. Standard Tolerance Limits (Permissible Deviations)

A motor cannot perfectly match its theoretical design. Therefore, GB/T 755 prescribes strict "Tolerance Limits" for performance variations. If a manufacturer's motor exceeds these deviations during type testing, it is considered non-compliant.

Parameter Standard Permissible Tolerance (GB/T 755)
Efficiency ($\eta$) $-15\% \times (1 - \eta)$ for motors $\le 150\text{kW}$
Rated Speed ($n_N$) $\pm 20\%$ of the designated value
Locked-Rotor Torque $-15\%$ of the declared value (Minimum limit)
Moment of Inertia $\pm 10\%$ of the declared value

4. No-Load Characteristics

Standards also require measuring the No-Load Speed and No-Load Current at rated voltage. These parameters are essential indicators of internal friction, magnetic alignment quality, and core losses within the stator.

5. Visual Representation (Instruction for Website Layout)

[Image Placement: Standard Nameplate and Torque-Speed Chart]

  • What to show: A detailed graphic split into two parts:

    1. Left side: A mockup of a professional, standard-compliant BLDC motor metal nameplate containing fields like Model, $P_N$, $U_N$, $n_N$, IP Grade, and Insulation Class.

    2. Right side: A Torque-Speed graph highlighting the "Continuous Zone" (shaded green) and the "Peak/Intermittent Zone" (shaded yellow), clearly labeling the Rated Point ($T_N, n_N$) and Stall Torque ($T_s$).