Selecting a micro magnetic gear pump is not simply a matter of choosing the largest flow rate or the smallest pump available.

For OEM engineers, the correct pump must match the complete operating point:

Required Flow + Differential Pressure + Fluid + Viscosity + Temperature + Suction + Duty Cycle + Materials + Motor

Boyang Motor's current micro magnetic gear pump range covers applications from low-flow precision dosing to high-flow industrial fluid transfer and circulation. Depending on configuration, the current range covers approximately 0.2 to 26 ml/rev displacement and flow rates up to 65 L/min.

1. Start With the Required Flow

The first step is to define the actual required flow.

Do not use only the maximum flow stated by the system designer. Identify:

  • Minimum required flow

  • Normal operating flow

  • Maximum required flow

  • Continuous or intermittent operation

  • Required speed-control range

For a positive-displacement gear pump, theoretical flow is approximately:

Theoretical Flow = Displacement × RPM

For example:

A 3.5 ml/rev pump operating at 2,000 rpm has a theoretical displacement of approximately 7 L/min before considering volumetric efficiency and system conditions.

Actual flow is affected by differential pressure, viscosity, temperature, internal leakage, speed and pump configuration.

2. Current Boyang Micro Magnetic Gear Pump Range

The current product family is broader than the previous BYMP020–BYMP350 structure.

Series Displacement Options Maximum Listed Flow
BYMP020 0.2 / 0.39 / 0.6 / 0.7 ml/rev Up to 2.2 L/min
BYMP030 1.0 / 1.2 / 1.7 / 1.9 ml/rev Up to 6.0 L/min
BYMP060 2.4 / 3.5 ml/rev Up to 10.5 L/min
BYMP070 4 / 6 / 9 / 12 / 17 ml/rev Up to 55 L/min
BYMP100 26 ml/rev Up to 65 L/min

Most current configurations operate within approximately 100–4000 rpm, with the actual usable range depending on pump size, fluid, pressure, temperature and motor configuration.

This means engineers can select the displacement according to the required operating point instead of selecting a pump only by model number.

3. Displacement Is Not the Same as Flow

This is one of the most common mistakes in pump selection.

Displacement is normally expressed in ml/rev.

Flow is normally expressed in L/min.

A pump with a larger displacement can produce more flow at the same RPM, but the final flow depends on operating conditions.

For example, a higher-displacement pump may allow the required flow to be reached at a lower motor speed.

That can be useful when the system requires:

  • Lower motor noise

  • Lower pump speed

  • Reduced mechanical stress

  • Longer operating life

  • Higher flow without excessive RPM

On the other hand, a smaller displacement pump can be more suitable for low-flow dosing and fine speed control.

4. Differential Pressure vs. System Pressure

Engineers should always distinguish between these two parameters.

Differential pressure:

ΔP = Outlet Pressure − Inlet Pressure

This is the pressure difference the pump must generate while delivering the required flow.

System withstand pressure is different.

A system may be capable of withstanding 40 bar static pressure without meaning that the pump should continuously generate 40 bar differential pressure.

For the current BYMP family, several configurations are specified for approximately 20–30 bar differential pressure with water delivery, while certain models/configurations have 25–40 bar system withstand pressure.

The actual allowable operating point must be confirmed from the specific pump configuration and performance curve.

5. Fluid Viscosity Changes Pump Selection

Viscosity can significantly affect pump performance.

Higher viscosity may increase:

  • Motor torque

  • Starting torque

  • Pressure loss

  • Heat generation

  • Pumping power

It can also influence internal leakage and volumetric efficiency.

Therefore, an engineer should provide viscosity in cP or mPa·s, together with the expected operating temperature.

A pump selected using water data may behave very differently when handling oil, syrup, coolant, chemicals or other viscous liquids.

6. Temperature and Materials

The current BYMP family can be configured for demanding temperature environments, with product configurations covering approximately -120°C to 150°C.

However, the temperature capability of a complete pump depends on:

  • Fluid

  • Pump body

  • Gear material

  • Bearing material

  • Shaft material

  • O-ring material

  • Magnetic drive construction

  • Motor temperature

Available material options can include:

  • SS316 / SS316L

  • Hastelloy

  • Special engineering plastics

  • Filled PEEK gears

  • Ceramic components

  • Zirconia ceramic shafts

  • FKM

  • EPDM

  • PTFE

  • FVMQ

  • CR

Material compatibility should therefore be evaluated using the actual fluid and temperature rather than a general material chart alone.

7. Suction and Self-Priming Requirements

If the pump is installed above the reservoir, suction performance becomes important.

The current micro magnetic gear pump configurations can provide inlet vacuum capability around -0.85 bar, depending on speed and configuration.

Some applications also require operation during the initial period when air remains in the suction line.

This should be evaluated separately from normal liquid pumping.

Important parameters include:

  • Reservoir height

  • Suction tubing diameter

  • Tubing length

  • Fluid viscosity

  • Inlet filter

  • Pump speed

  • Air volume in the suction line

8. Inlet Filtration

Small gear pumps are sensitive to contamination.

For current BYMP configurations, a 400-mesh inlet filter is commonly recommended.

The filter itself must also be included in the hydraulic calculation because a fine filter can create significant pressure loss, particularly when:

  • Flow is high

  • Fluid is viscous

  • Filter becomes contaminated

The pump should therefore be selected using the actual pressure drop across the complete inlet circuit.

9. Noise and Gear Selection

Noise depends on more than the motor.

Potential sources include:

  • Gear meshing

  • Pump speed

  • Pressure fluctuation

  • Motor vibration

  • Mounting structure

  • Tubing resonance

  • System acoustics

Current BYMP020, BYMP030 and BYMP060 configurations can achieve noise levels below approximately 55 dB at 2000 rpm in specified straight-gear configurations.

Some BYMP020 configurations also offer a helical gear option for lower noise.

The appropriate gear configuration depends on the application's priority between pressure capability, flow stability and acoustic performance.

10. Selecting the Pump by Application

A practical first-pass selection can be:

Low-flow precision dosing

→ BYMP020

Small-to-medium laboratory, medical or chemical fluid handling

→ BYMP030

Medium-flow dosing, transfer and circulation

→ BYMP060

Higher-flow industrial and cooling applications

→ BYMP070

High-flow fluid transfer and circulation

→ BYMP100

These are starting points, not automatic selections.

The final model should be determined from the complete operating point.

11. Magnetic Drive for Leakage-Sensitive Applications

A magnetic drive separates the motor drive from the pumped-fluid chamber.

Torque is transmitted through a static isolation barrier instead of a rotating shaft passing through a conventional dynamic seal.

This architecture is particularly useful for:

  • Chemical fluids

  • DEF/AdBlue

  • Reagents

  • Coolants

  • Corrosive liquids

  • Contamination-sensitive fluids

  • Long-duty-cycle equipment

The actual sealing performance still depends on the complete pump construction and material selection.

12. OEM Selection Checklist

Before requesting a quotation, an engineer can provide:

  1. Required flow

  2. Differential pressure

  3. Fluid name

  4. Viscosity

  5. Minimum / normal / maximum temperature

  6. Suction lift or inlet vacuum

  7. Duty cycle

  8. Supply voltage

  9. Required RPM

  10. Port size

  11. Wetted materials

  12. Noise requirement

  13. Installation dimensions

  14. Control method

  15. Expected service life

This information allows the pump, motor and controller to be evaluated as one system.

FAQ

What is the current flow range of Boyang micro magnetic gear pumps?

The current product family covers applications from low-flow dosing to high-flow transfer and circulation, with the highest listed configuration reaching approximately 65 L/min.

What is the current displacement range?

The current range covers approximately 0.2 to 26 ml/rev, depending on the series and configuration.

Does a 40 bar system rating mean the pump continuously produces 40 bar differential pressure?

No. System withstand pressure and differential operating pressure are different parameters. The actual differential-pressure capability must be evaluated at the required flow, fluid and operating conditions.

Can Boyang customize the pump?

Yes. Pump materials, seals, gears, ports, motor configuration and other OEM parameters can be evaluated according to the application.

For OEM selection, the most useful starting point is not the pump model. It is the complete operating point.