High-Pressure Micro Gear Pumps for Battery & New Energy Coolant Loops
Brushless DC Gear Pumps

High-Pressure Micro Gear Pumps for Battery & New Energy Coolant Loops

2026-08-27

High-Pressure Micro Gear Pumps for Battery & New Energy Coolant Loops

Battery packs, energy-storage systems and high-power electronics increasingly require compact liquid-cooling circuits with controlled flow and reliable pressure handling.

For OEM engineers, the challenge is not simply selecting a pump with a high maximum flow rate.

The pump must match:

Required Flow + Differential Pressure + Coolant + Temperature + System Pressure + Duty Cycle + Installation Space

Boyang's current micro magnetic gear pump range now covers configurations from low-flow precision circulation to high-flow coolant transfer, with selected models reaching up to 65 L/min.

1. Why Pump Selection Matters in High-Pressure Cooling Loops

A liquid-cooling circuit can include:

  • Battery modules

  • Cold plates

  • Heat exchangers

  • Valves

  • Filters

  • Quick connectors

  • Long tubing

  • Reservoirs

Each component contributes pressure loss.

Therefore, a pump rated for a high system pressure does not automatically provide the required flow at that pressure.

Engineers should calculate the actual differential pressure at the required coolant flow.

2. Differential Pressure vs. System Withstand Pressure

This distinction is particularly important in new-energy cooling systems.

Differential pressure is the pressure generated between pump inlet and outlet.

System withstand pressure is the pressure the pump/system structure can tolerate.

Current BYMP configurations can provide approximately 20–30 bar differential pressure for water delivery, while selected configurations provide 25–40 bar system withstand pressure.

These numbers should not be treated as interchangeable.

For glycol, coolant mixtures or other fluids, the actual performance may differ from water testing.

3. Current BYMP Models for Higher-Flow Applications

The current product family includes:

Series Displacement Maximum Listed Flow
BYMP060 2.4 / 3.5 ml/rev Up to 10.5 L/min
BYMP070 4 / 6 / 9 / 12 / 17 ml/rev Up to 55 L/min
BYMP100 26 ml/rev Up to 65 L/min

This gives engineers considerably more flexibility than the previous 150/200/350 model structure.

For compact battery cooling systems, BYMP060 may be suitable for relatively moderate flow requirements.

For higher-flow coolant circulation, BYMP070 and BYMP100 provide larger displacement options.

4. Flow Depends on More Than Pump Size

For a gear pump:

Theoretical Flow = Displacement × RPM

However, actual coolant flow depends on:

  • Coolant viscosity

  • Differential pressure

  • Temperature

  • RPM

  • Internal leakage

  • Pump configuration

  • Piping resistance

A higher displacement pump operated at lower RPM can sometimes achieve the required flow without pushing the motor to unnecessarily high speed.

This can be useful for acoustic and thermal management.

5. Coolant Viscosity and Temperature

Battery coolants may contain glycol or other additives.

Viscosity changes with temperature.

At low temperature, the coolant may become more viscous, increasing:

  • Starting torque

  • Pumping power

  • Pressure loss

  • Motor load

At higher temperatures, viscosity may decrease while material and motor-temperature considerations become more important.

Therefore, pump validation should include the actual coolant across the expected temperature range.

6. Magnetic Drive Architecture

A magnetic drive transfers motor torque to the internal gear set without requiring a rotating shaft to pass through the fluid boundary.

This can reduce the leakage risk associated with dynamic shaft seals.

For coolant systems where long-term sealing reliability is important, this architecture can simplify the fluid boundary.

Available wetted materials may include:

  • SS316 / SS316L

  • Hastelloy

  • Engineering plastics

  • Filled PEEK

  • Ceramic

  • Zirconia ceramic

  • Application-specific sealing materials

The correct material combination should be selected against the actual coolant chemistry and temperature.

7. Compact Cooling System Integration

Space is often limited around:

  • Battery modules

  • Inverters

  • Power electronics

  • Fuel-cell systems

  • Energy-storage cabinets

A compact magnetic gear pump can combine positive-displacement flow control with variable-speed BLDC operation.

The pump can be controlled according to thermal load rather than operating continuously at maximum speed.

For example:

Low thermal load → lower pump speed

High thermal load → higher pump speed

This can help match coolant circulation to the actual thermal requirement.

8. Inlet Filter and Contamination

The cooling circuit should be evaluated for contamination and particle generation.

A 400-mesh inlet filter is commonly recommended for current BYMP configurations.

However, the filter pressure drop must be included in the pump calculation.

A clogged filter can substantially increase inlet restriction and change the pump operating point.

9. Temperature Range

Selected BYMP configurations cover approximately -120°C to 150°C.

The actual allowable temperature depends on:

  • Coolant chemistry

  • Gear material

  • Bearing material

  • Shaft material

  • Seal material

  • Magnetic drive

  • Motor temperature

The temperature specification should therefore be confirmed for the final configuration rather than treated as a universal rating for every possible fluid.

10. OEM Selection Checklist

For a battery or new-energy cooling application, provide:

  • Coolant type

  • Flow requirement

  • Differential pressure

  • Minimum temperature

  • Normal temperature

  • Maximum temperature

  • System pressure

  • Reservoir location

  • Tubing size

  • Filter specification

  • Duty cycle

  • Supply voltage

  • Control signal

  • Installation dimensions

With these parameters, the appropriate BYMP series and BLDC motor configuration can be evaluated together.

FAQ

Can these pumps be used in battery cooling loops?

Yes, selected BYMP configurations can be evaluated for battery, energy-storage and power-electronics cooling applications.

What is the highest current flow configuration?

The current BYMP100 configuration is listed up to approximately 65 L/min.

Does the 40 bar rating mean continuous 40 bar differential pressure?

No. The 25–40 bar figure refers to system withstand pressure for applicable configurations. Differential operating pressure must be evaluated separately.

Which model should be used for a high-flow coolant loop?

For higher-flow requirements, BYMP070 and BYMP100 provide the largest current displacement and flow configurations. The final choice depends on the actual flow, pressure, coolant and temperature.

A cooling pump should always be selected from the complete hydraulic operating point rather than maximum flow alone.