In a three-phase BLDC motor, Hall sensors are typically arranged in a triplet, spaced $120^\circ$ electrical degrees apart. The corresponding mechanical spacing can be calculated based on the number of rotor pole pairs. To ensure optimal performance, the following three key aspects must be controlled:

  • 1. Hall Lead Angle (Advance Angle)

    If the motor rotates in only one direction, the Hall lead angle can be set to any fixed optimal value. However, if bidirectional rotation (reversing) is required, it is important to note that a phase lead in the forward direction will inherently become a phase lag in the reverse direction. To mitigate this, a $30^\circ$ lead angle can be designed, combined with a phase adjustment during reverse rotation to keep the lead angle close to $30^\circ$ in both directions.

  • 2. Placement Accuracy of the Three Hall Sensors

    The physical positioning of the Hall sensors must be as precise as possible. Misalignment will cause asymmetrical commutation intervals, leading to torque ripple and reduced efficiency.

  • 3. Mitigation of Stator Interference