How to Calculate Micro Gear Pump Flow Rate: ml/rev, RPM & Efficiency
Calculating micro gear pump flow rate is relatively simple because gear pumps are positive-displacement pumps.
The basic calculation uses three key parameters:
Pump Displacement × RPM × Volumetric Efficiency
Understanding this relationship helps engineers select the correct micro gear pump and BLDC motor for a required flow rate.
Quick Answer: Micro Gear Pump Flow Formula
The basic theoretical flow formula is:
Qₜ = V × RPM
For L/min:
Qₜ (L/min) = V (ml/rev) × RPM ÷ 1000
Where:
-
Qₜ = theoretical flow
-
V = pump displacement in ml/rev
-
RPM = pump speed
For actual flow, volumetric efficiency must also be considered:
Qₐ = V × RPM × ηᵥ
Where:
-
Qₐ = actual flow
-
ηᵥ = volumetric efficiency
For example:
A 1.0 ml/rev micro gear pump running at 3,000 RPM with 90% volumetric efficiency produces approximately:
1.0 × 3,000 × 90% ÷ 1000 = 2.7 L/min
1. What Does ml/rev Mean?
Pump displacement is commonly specified as ml/rev, or milliliters per revolution.
It represents the theoretical volume moved by the pump during one complete revolution.
For example:
| Pump Displacement | Theoretical Volume per Revolution |
|---|---|
| 0.2 ml/rev | 0.2 ml |
| 0.5 ml/rev | 0.5 ml |
| 1.0 ml/rev | 1.0 ml |
| 2.0 ml/rev | 2.0 ml |
| 3.5 ml/rev | 3.5 ml |
A larger displacement pump moves more fluid per revolution.
However, it does not necessarily mean that a larger pump is always the better choice. Required flow, pressure, RPM and motor torque must all be considered.
For pump selection, see:
https://www.boyangmotor.com/news/how-to-select-micro-magnetic-gear-pump/
2. How RPM Affects Flow Rate
For a positive-displacement gear pump, flow generally increases as RPM increases.
For a 1.0 ml/rev pump:
| RPM | Theoretical Flow |
|---|---|
| 500 | 0.50 L/min |
| 1,000 | 1.00 L/min |
| 2,000 | 2.00 L/min |
| 3,000 | 3.00 L/min |
| 4,000 | 4.00 L/min |
This is theoretical flow before accounting for volumetric efficiency.
This relationship also makes BLDC motors useful for micro gear pumps.
By controlling motor speed, the system can adjust pump flow without changing the mechanical pump.
For OEM systems:
Higher RPM → Higher Flow
within the pump's specified operating range.
3. Why Actual Flow Is Lower Than Theoretical Flow
A real gear pump has internal clearances between components.
Some fluid can move from the high-pressure outlet side back toward the low-pressure inlet side.
This internal leakage is commonly called slip.
As a result:
Actual Flow < Theoretical Flow
The difference is represented by volumetric efficiency.
For example:
Theoretical flow
1.0 ml/rev × 3,000 RPM
= 3.0 L/min
With 90% volumetric efficiency
3.0 × 90%
= 2.7 L/min
Therefore, using the theoretical formula alone can overestimate the actual flow.
4. How Pressure Affects Flow
Differential pressure is one of the main factors affecting volumetric efficiency.
As differential pressure increases, internal leakage can increase.
Therefore, a pump may produce:
3.0 L/min at low pressure
but significantly less at:
10 bar differential pressure
The correct engineering question is therefore not:
"What is the maximum flow of this pump?"
It is:
"What flow can the pump deliver at my required pressure?"
For more information:
https://www.boyangmotor.com/news/gear-pump-pressure-differential-vs-system-pressure/
5. How Viscosity Affects Flow
Fluid viscosity also changes pump performance.
With very low-viscosity fluids, internal leakage can become more significant.
Higher-viscosity fluids can reduce leakage, but they also increase mechanical and hydraulic resistance.
Higher viscosity can increase:
-
Required motor torque
-
Starting torque
-
Motor current
-
Heat generation
-
Pressure losses
Therefore, flow calculations should use the fluid's actual viscosity whenever possible.
Read more:
https://www.boyangmotor.com/news/micro-gear-pump-viscosity-flow-pressure-motor-torque/
6. How to Calculate Required RPM
If the required flow and pump displacement are known, RPM can be estimated from:
RPM = Required Flow × 1000 ÷ Displacement
For example:
Required flow:
2.0 L/min
Pump displacement:
0.5 ml/rev
Then:
RPM = 2.0 × 1000 ÷ 0.5
RPM = 4,000 RPM
This is the theoretical RPM.
If the pump operates at 90% volumetric efficiency, the required RPM will be higher.
A more practical calculation is:
RPM = Required Flow × 1000 ÷ (Displacement × Volumetric Efficiency)
For the same example:
RPM = 2,000 ÷ (0.5 × 0.90)
≈ 4,444 RPM
If the selected pump is limited to 4,000 RPM, a larger displacement pump may be required.
7. How to Select Pump Displacement From Required Flow
The same calculation can be used in reverse.
Example
Required flow:
1.5 L/min
Target speed:
2,000 RPM
Assumed volumetric efficiency:
90%
Required displacement:
V = Flow × 1000 ÷ (RPM × Efficiency)
V = 1,500 ÷ (2,000 × 0.90)
V ≈ 0.83 ml/rev
A pump around 0.8–1.0 ml/rev would therefore be a reasonable starting point.
The final selection should be verified using the manufacturer's actual performance curve.
8. Micro Gear Pump Flow Conversion
Engineers often need to convert between different flow units.
Common conversions
1 L/min = 1,000 ml/min
1 L/min = 60 L/h
1 ml/min = 0.001 L/min
For example:
2.5 L/min
= 2,500 ml/min
= 150 L/h
These conversions are useful when comparing pump specifications with system requirements.
9. Boyang Micro Magnetic Gear Pump Displacement
Boyang's micro magnetic gear pump range includes several displacement classes, approximately from:
0.2 ml/rev to 3.5 ml/rev
Examples include:
| Displacement | Typical Application Direction |
|---|---|
| 0.2 ml/rev | Very low-flow dosing |
| 0.3–0.7 ml/rev | Compact fluid control |
| 1.0–1.5 ml/rev | General fluid circulation |
| 1.9–2.0 ml/rev | Higher-flow applications |
| 3.5 ml/rev | Higher-flow transfer |
The actual flow depends on RPM, pressure, fluid viscosity and temperature.
Product information:
https://www.boyangmotor.com/brushless-gear-pump/
10. Flow Rate Example: 0.5 ml/rev Pump
Consider a micro gear pump with:
-
Displacement: 0.5 ml/rev
-
Speed: 3,000 RPM
-
Volumetric efficiency: 90%
Step 1 — Calculate theoretical flow
0.5 × 3,000 ÷ 1,000
= 1.5 L/min
Step 2 — Apply efficiency
1.5 × 90%
= 1.35 L/min
Therefore, the estimated actual flow is:
≈ 1.35 L/min
The final flow should still be confirmed at the actual operating pressure and fluid conditions.
11. Flow Rate and BLDC Motor Speed Control
One advantage of combining a micro gear pump with a BLDC motor is adjustable flow.
For example:
1,000 RPM → Low Flow
2,000 RPM → Medium Flow
3,000 RPM → Higher Flow
The controller can adjust motor speed according to the required system flow.
This makes a BLDC-driven gear pump suitable for applications requiring:
-
Variable flow
-
Programmable dosing
-
Closed-loop flow control
-
Compact fluid circulation
-
Automated equipment
However, increasing RPM also affects motor load, temperature and pump operating life.
For motor-pump matching:
https://www.boyangmotor.com/news/how-to-match-a-bldc-motor-with-a-micro-gear-pump/
12. Why Flow Rate Changes During Real Operation
Even if pump RPM remains constant, actual flow may change because of:
-
Differential pressure
-
Fluid viscosity
-
Fluid temperature
-
Internal leakage
-
Pump wear
-
Motor speed variation
-
Fluid properties
Therefore, a specification such as:
2 L/min @ 2,000 RPM
is much more useful than simply saying:
Maximum Flow: 3 L/min
The operating conditions should always be considered.
Micro Gear Pump Flow Calculation Checklist
Before calculating or selecting a pump, confirm:
| Parameter | Example |
|---|---|
| Required flow | 2.0 L/min |
| Pump displacement | 1.0 ml/rev |
| Operating speed | 2,000 RPM |
| Differential pressure | 10 bar |
| Fluid viscosity | 1–10 cP |
| Fluid temperature | 60°C |
| Volumetric efficiency | 90% |
| Motor voltage | 24 VDC |
With these parameters, the pump and BLDC motor can be evaluated as a complete system.
Frequently Asked Questions
How do you calculate micro gear pump flow rate?
Use:
Flow = Displacement × RPM × Volumetric Efficiency
For L/min, divide the result by 1,000 when displacement is expressed in ml/rev.
Does increasing RPM increase gear pump flow?
Generally yes, within the specified operating range.
However, actual flow also depends on pressure, viscosity, temperature and volumetric efficiency.
What is ml/rev in a gear pump?
ml/rev means the theoretical fluid displacement for one revolution of the pump.
Why is actual flow lower than theoretical flow?
Internal leakage or slip causes the actual flow to be lower than theoretical displacement, particularly as differential pressure increases.
Can a BLDC motor control gear pump flow?
Yes. A BLDC motor can control pump RPM electronically, allowing the flow rate to be adjusted according to system requirements.
Conclusion
Calculating micro gear pump flow rate starts with a simple relationship:
Flow = Displacement × RPM × Volumetric Efficiency
But accurate pump selection requires more than this formula.
Engineers should also consider:
Differential Pressure + Viscosity + Temperature + Motor Torque
For OEM applications, the most useful specification is not simply the pump's maximum flow, but its actual flow at the required pressure, speed and fluid conditions.
Boyang Motor provides micro magnetic gear pump configurations from approximately 0.2 to 3.5 ml/rev, with different motor, material and pressure configurations for precision dosing, cooling, chemical handling and industrial fluid systems.
For a complete pump selection, see:
https://www.boyangmotor.com/news/how-to-select-micro-magnetic-gear-pump/
Or explore the micro magnetic gear pump range:
https://www.boyangmotor.com/brushless-gear-pump/

Products
Brushless Motor
16mm Brushless
24mm Brushless
28mm Brushless
30mm Brushless
57mm Brushless
60mm BLDC
92mm BLDC
150mm BLDC
DC Brush Motor
30mm Brush
36mm Brush
38mm Brush
42mm Brush
52mm Brush
80mm Brush
90mm Brush
Brushless Gear Pump
20 Gear Pump
30 Gear Pump
60 Gear Pump
100 Gear Pump
150 Gear Pump
200 Gear Pump
350 Gear Pump
Brushless Fan/Blower
25 Cross Flow Fan
30 Cross Flow Fan
40 Cross Flow Fan
50 Cross Flow Fan
60 Cross Flow Fan
90 Cross Flow Fan
120 Cross Flow Fan
Servo Motor
40 Servo Motor
60 Servo Motor
80 Servo Motor
110 Servo Motor
130 Servo Motor
180 Servo Motor
Planerary Gearbox
22 Planetary Gear
28 Planetary Gear
32 Planetary Gear
36 Planetary Gear
42 Planetary Gear
60 Planetary Gear
90 Planetary Gear
120 Planetary Gear
Motor Controller
3A Integrated Controller
5A Integrated Controller
8A Integrated Controller
3A BLDC Controller
15A BLDC Controller
50A BLDC Controller
AC BLDC Driver
Panel Driver
Custom Parts
Speed Regulating
Dissipating Housing
Connector
Motor Bracket
Custom Solutions