How to Calculate Micro Gear Pump Flow Rate: ml/rev, RPM & Efficiency
Brushless DC Gear Pumps

How to Calculate Micro Gear Pump Flow Rate: ml/rev, RPM & Efficiency

2026-08-18

Calculating micro gear pump flow rate is relatively simple because gear pumps are positive-displacement pumps.

The basic calculation uses three key parameters:

Pump Displacement × RPM × Volumetric Efficiency

Understanding this relationship helps engineers select the correct micro gear pump and BLDC motor for a required flow rate.


Quick Answer: Micro Gear Pump Flow Formula

The basic theoretical flow formula is:

Qₜ = V × RPM

For L/min:

Qₜ (L/min) = V (ml/rev) × RPM ÷ 1000

Where:

  • Qₜ = theoretical flow

  • V = pump displacement in ml/rev

  • RPM = pump speed

For actual flow, volumetric efficiency must also be considered:

Qₐ = V × RPM × ηᵥ

Where:

  • Qₐ = actual flow

  • ηᵥ = volumetric efficiency

For example:

A 1.0 ml/rev micro gear pump running at 3,000 RPM with 90% volumetric efficiency produces approximately:

1.0 × 3,000 × 90% ÷ 1000 = 2.7 L/min


1. What Does ml/rev Mean?

Pump displacement is commonly specified as ml/rev, or milliliters per revolution.

It represents the theoretical volume moved by the pump during one complete revolution.

For example:

Pump Displacement Theoretical Volume per Revolution
0.2 ml/rev 0.2 ml
0.5 ml/rev 0.5 ml
1.0 ml/rev 1.0 ml
2.0 ml/rev 2.0 ml
3.5 ml/rev 3.5 ml

A larger displacement pump moves more fluid per revolution.

However, it does not necessarily mean that a larger pump is always the better choice. Required flow, pressure, RPM and motor torque must all be considered.

For pump selection, see:

https://www.boyangmotor.com/news/how-to-select-micro-magnetic-gear-pump/


2. How RPM Affects Flow Rate

For a positive-displacement gear pump, flow generally increases as RPM increases.

For a 1.0 ml/rev pump:

RPM Theoretical Flow
500 0.50 L/min
1,000 1.00 L/min
2,000 2.00 L/min
3,000 3.00 L/min
4,000 4.00 L/min

This is theoretical flow before accounting for volumetric efficiency.

This relationship also makes BLDC motors useful for micro gear pumps.

By controlling motor speed, the system can adjust pump flow without changing the mechanical pump.

For OEM systems:

Higher RPM → Higher Flow

within the pump's specified operating range.


3. Why Actual Flow Is Lower Than Theoretical Flow

A real gear pump has internal clearances between components.

Some fluid can move from the high-pressure outlet side back toward the low-pressure inlet side.

This internal leakage is commonly called slip.

As a result:

Actual Flow < Theoretical Flow

The difference is represented by volumetric efficiency.

For example:

Theoretical flow

1.0 ml/rev × 3,000 RPM

= 3.0 L/min

With 90% volumetric efficiency

3.0 × 90%

= 2.7 L/min

Therefore, using the theoretical formula alone can overestimate the actual flow.


4. How Pressure Affects Flow

Differential pressure is one of the main factors affecting volumetric efficiency.

As differential pressure increases, internal leakage can increase.

Therefore, a pump may produce:

3.0 L/min at low pressure

but significantly less at:

10 bar differential pressure

The correct engineering question is therefore not:

"What is the maximum flow of this pump?"

It is:

"What flow can the pump deliver at my required pressure?"

For more information:

https://www.boyangmotor.com/news/gear-pump-pressure-differential-vs-system-pressure/


5. How Viscosity Affects Flow

Fluid viscosity also changes pump performance.

With very low-viscosity fluids, internal leakage can become more significant.

Higher-viscosity fluids can reduce leakage, but they also increase mechanical and hydraulic resistance.

Higher viscosity can increase:

  • Required motor torque

  • Starting torque

  • Motor current

  • Heat generation

  • Pressure losses

Therefore, flow calculations should use the fluid's actual viscosity whenever possible.

Read more:

https://www.boyangmotor.com/news/micro-gear-pump-viscosity-flow-pressure-motor-torque/


6. How to Calculate Required RPM

If the required flow and pump displacement are known, RPM can be estimated from:

RPM = Required Flow × 1000 ÷ Displacement

For example:

Required flow:

2.0 L/min

Pump displacement:

0.5 ml/rev

Then:

RPM = 2.0 × 1000 ÷ 0.5

RPM = 4,000 RPM

This is the theoretical RPM.

If the pump operates at 90% volumetric efficiency, the required RPM will be higher.

A more practical calculation is:

RPM = Required Flow × 1000 ÷ (Displacement × Volumetric Efficiency)

For the same example:

RPM = 2,000 ÷ (0.5 × 0.90)

≈ 4,444 RPM

If the selected pump is limited to 4,000 RPM, a larger displacement pump may be required.


7. How to Select Pump Displacement From Required Flow

The same calculation can be used in reverse.

Example

Required flow:

1.5 L/min

Target speed:

2,000 RPM

Assumed volumetric efficiency:

90%

Required displacement:

V = Flow × 1000 ÷ (RPM × Efficiency)

V = 1,500 ÷ (2,000 × 0.90)

V ≈ 0.83 ml/rev

A pump around 0.8–1.0 ml/rev would therefore be a reasonable starting point.

The final selection should be verified using the manufacturer's actual performance curve.


8. Micro Gear Pump Flow Conversion

Engineers often need to convert between different flow units.

Common conversions

1 L/min = 1,000 ml/min

1 L/min = 60 L/h

1 ml/min = 0.001 L/min

For example:

2.5 L/min

= 2,500 ml/min

= 150 L/h

These conversions are useful when comparing pump specifications with system requirements.


9. Boyang Micro Magnetic Gear Pump Displacement

Boyang's micro magnetic gear pump range includes several displacement classes, approximately from:

0.2 ml/rev to 3.5 ml/rev

Examples include:

Displacement Typical Application Direction
0.2 ml/rev Very low-flow dosing
0.3–0.7 ml/rev Compact fluid control
1.0–1.5 ml/rev General fluid circulation
1.9–2.0 ml/rev Higher-flow applications
3.5 ml/rev Higher-flow transfer

The actual flow depends on RPM, pressure, fluid viscosity and temperature.

Product information:

https://www.boyangmotor.com/brushless-gear-pump/


10. Flow Rate Example: 0.5 ml/rev Pump

Consider a micro gear pump with:

  • Displacement: 0.5 ml/rev

  • Speed: 3,000 RPM

  • Volumetric efficiency: 90%

Step 1 — Calculate theoretical flow

0.5 × 3,000 ÷ 1,000

= 1.5 L/min

Step 2 — Apply efficiency

1.5 × 90%

= 1.35 L/min

Therefore, the estimated actual flow is:

≈ 1.35 L/min

The final flow should still be confirmed at the actual operating pressure and fluid conditions.


11. Flow Rate and BLDC Motor Speed Control

One advantage of combining a micro gear pump with a BLDC motor is adjustable flow.

For example:

1,000 RPM → Low Flow

2,000 RPM → Medium Flow

3,000 RPM → Higher Flow

The controller can adjust motor speed according to the required system flow.

This makes a BLDC-driven gear pump suitable for applications requiring:

  • Variable flow

  • Programmable dosing

  • Closed-loop flow control

  • Compact fluid circulation

  • Automated equipment

However, increasing RPM also affects motor load, temperature and pump operating life.

For motor-pump matching:

https://www.boyangmotor.com/news/how-to-match-a-bldc-motor-with-a-micro-gear-pump/


12. Why Flow Rate Changes During Real Operation

Even if pump RPM remains constant, actual flow may change because of:

  • Differential pressure

  • Fluid viscosity

  • Fluid temperature

  • Internal leakage

  • Pump wear

  • Motor speed variation

  • Fluid properties

Therefore, a specification such as:

2 L/min @ 2,000 RPM

is much more useful than simply saying:

Maximum Flow: 3 L/min

The operating conditions should always be considered.


Micro Gear Pump Flow Calculation Checklist

Before calculating or selecting a pump, confirm:

Parameter Example
Required flow 2.0 L/min
Pump displacement 1.0 ml/rev
Operating speed 2,000 RPM
Differential pressure 10 bar
Fluid viscosity 1–10 cP
Fluid temperature 60°C
Volumetric efficiency 90%
Motor voltage 24 VDC

With these parameters, the pump and BLDC motor can be evaluated as a complete system.


Frequently Asked Questions

How do you calculate micro gear pump flow rate?

Use:

Flow = Displacement × RPM × Volumetric Efficiency

For L/min, divide the result by 1,000 when displacement is expressed in ml/rev.


Does increasing RPM increase gear pump flow?

Generally yes, within the specified operating range.

However, actual flow also depends on pressure, viscosity, temperature and volumetric efficiency.


What is ml/rev in a gear pump?

ml/rev means the theoretical fluid displacement for one revolution of the pump.


Why is actual flow lower than theoretical flow?

Internal leakage or slip causes the actual flow to be lower than theoretical displacement, particularly as differential pressure increases.


Can a BLDC motor control gear pump flow?

Yes. A BLDC motor can control pump RPM electronically, allowing the flow rate to be adjusted according to system requirements.


Conclusion

Calculating micro gear pump flow rate starts with a simple relationship:

Flow = Displacement × RPM × Volumetric Efficiency

But accurate pump selection requires more than this formula.

Engineers should also consider:

Differential Pressure + Viscosity + Temperature + Motor Torque

For OEM applications, the most useful specification is not simply the pump's maximum flow, but its actual flow at the required pressure, speed and fluid conditions.

Boyang Motor provides micro magnetic gear pump configurations from approximately 0.2 to 3.5 ml/rev, with different motor, material and pressure configurations for precision dosing, cooling, chemical handling and industrial fluid systems.

For a complete pump selection, see:

https://www.boyangmotor.com/news/how-to-select-micro-magnetic-gear-pump/

Or explore the micro magnetic gear pump range:

https://www.boyangmotor.com/brushless-gear-pump/

How to Calculate Micro Gear Pump Flow Rate.webp