How to Read a BLDC Motor Datasheet: Decoding Every Parameter
How to Read a BLDC Motor Datasheet: KV, Ke, Kt, Current, Torque and Power
A BLDC motor datasheet is more than a list of voltage, power and speed ratings. It describes a motor under specified electrical, mechanical and thermal conditions. To select a motor correctly, you need to understand both the relationships between the parameters and the definitions behind them.
The most common mistakes are comparing motors by wattage alone, confusing DC bus current with motor phase current, and converting KV, Ke and Kt without checking voltage and current conventions.
This guide explains how to read a brushless DC motor datasheet, check whether its ratings are consistent, and turn the available information into a practical OEM motor specification.
Boyang’s standard motor models serve as reference platforms for custom development. The final winding, dimensions, shaft, mounting, feedback, controller arrangement and protection requirements are confirmed for the customer’s equipment.
1. Quick Answer: How to Read a BLDC Motor Datasheet
Read a BLDC motor datasheet in this order:
- Define the operating requirement: continuous torque, speed, peak torque, peak duration and duty cycle.
- Confirm the supply and drive: voltage range, controller type, current limits and feedback requirements.
- Check parameter definitions: bus or phase current, RMS or peak, phase or line-to-line resistance, and back-EMF measurement convention.
- Compare performance: rated torque, rated speed, shaft output power and the torque-speed operating envelope.
- Check limits and installation: temperature, cooling, mounting, shaft loading, connectors and environmental protection.
KV, Ke and Kt are related, but their numerical conversion depends on how the manufacturer defines the electrical quantities. Do not assume that matching units alone makes two datasheets comparable.
The practical selection question is:
Can this motor and controller provide my required continuous torque at my operating speed, under my installation and cooling conditions, while also meeting the peak-load requirement?
2. Start with Definitions and Test Conditions
A BLDC motor datasheet describes a particular motor configuration. Ratings may depend on winding version, controller, supply voltage, mounting, cooling and ambient temperature.
Before calculating anything, confirm which configuration the sheet describes and what conditions apply.
| Item | What to Confirm | Why It Matters |
|---|---|---|
| Motor configuration | Model, winding version, accessories and document revision | One frame size may have several electrical configurations |
| Voltage | DC bus input, winding voltage or integrated-drive supply | These are not automatically interchangeable |
| Current | Bus current, phase current, RMS value or waveform peak | Affects torque, heating and controller selection |
| Resistance | Per phase or line-to-line, winding connection and temperature | Required for a valid copper-loss calculation |
| Back EMF | Phase or line-to-line, RMS or peak, and waveform | Required before converting Ke to another convention |
| Continuous ratings | Ambient temperature, mounting, cooling and duty | Continuous capability depends on heat removal |
| Efficiency | Operating point and whether controller losses are included | Motor efficiency and drive-system efficiency are different |
If a definition is missing, request clarification rather than choosing the most convenient interpretation.
3. Understand KV, Ke and Torque Constant Kt
These constants describe the relationship between speed, induced voltage, current and electromagnetic torque.
| Parameter | Common Units | Meaning | Selection Use |
|---|---|---|---|
| Speed constant, KV | RPM/V | Speed per unit of voltage under the stated convention | Initial voltage-speed and winding evaluation |
| Back-EMF constant, Ke | V/(rad/s), V·s/rad or V/kRPM | Induced voltage per unit of rotational speed | Voltage headroom and controller evaluation |
| Torque constant, Kt | N·m/A, N·m/Arms or mN·m/A | Torque per unit of the specified current | Current required for an estimated torque |
3.1 What KV Tells You
A speed constant of 100 RPM/V suggests approximately 2,400 RPM at 24 V in a compatible idealized no-load model.
Actual no-load speed also depends on losses, controller operation and the definition used for the voltage. Loaded speed cannot be determined from KV and bus voltage alone.
KV does not specify rated power, continuous torque or maximum permissible speed.
3.2 What Ke Tells You
A rotating permanent-magnet motor generates back EMF. In the convention used to define Ke:
E = Ke × ω
Here, E is the corresponding induced voltage and ω is angular speed in rad/s when Ke is expressed in V·s/rad.
To convert the speed unit while preserving the same voltage definition:
Ke [V·s/rad] = Ke [V/kRPM] ÷ 104.72Ke [V/kRPM] = 104.72 × Ke [V·s/rad]
This conversion changes the speed unit only. It does not convert phase voltage to line-to-line voltage or RMS voltage to peak voltage.
3.3 What Kt Tells You
Within the range and current convention for which the constant applies:
Electromagnetic torque ≈ Kt × corresponding motor current
If Kt is specified in N·m/Arms, use the corresponding RMS motor current, not an arbitrary DC supply-current reading.
Also confirm whether the manufacturer’s torque convention refers to electromagnetic torque or a shaft-output approximation. Mechanical and magnetic losses can affect the useful shaft torque.
3.4 When Can You Use Kt = Ke = 9.5493 ÷ KV?
In a consistent ideal equivalent-motor convention, the torque and back-EMF constants are numerically equal in SI units:
Kt [N·m/A] = Ke [V·s/rad]
If KV uses the matching voltage convention:
Kt = Ke = 9.5493 ÷ KV
However, published three-phase BLDC and servo-motor datasheets may use different conventions for phase quantities, line-to-line quantities, RMS values, peak values and commutation methods.
Therefore, do not directly equate a published line-to-line Ke with a published Kt in N·m/Arms merely because Ke has been converted to V·s/rad. Additional convention-dependent factors may be required.
3.5 Illustrative Conversion Table
The following values apply only to the consistent ideal equivalent convention described above. They are not Boyang product specifications or a universal conversion table for all three-phase datasheets.
| KV (RPM/V) | Ke (V·s/rad) | Ke (V/kRPM) | Kt (N·m/A) |
|---|---|---|---|
| 50 | 0.1910 | 20 | 0.1910 |
| 100 | 0.09549 | 10 | 0.09549 |
| 200 | 0.04775 | 5 | 0.04775 |
| 400 | 0.02387 | 2.5 | 0.02387 |
| 1000 | 0.009549 | 1 | 0.009549 |
Under comparable definitions, a higher KV corresponds to less torque per amp. It does not establish which complete motor can deliver more continuous torque, because current capability and thermal performance also matter.
4. Distinguish Bus Current, Phase Current, RMS and Peak
A controller converts DC supply power into controlled motor-phase currents. The DC bus current and the motor phase current are not generally the same quantity.
| Current Description | What It Describes | Main Use |
|---|---|---|
| DC bus current | Current drawn from the DC supply by the drive | Supply sizing and DC input-power evaluation |
| Motor phase current | Current associated with the motor-phase output | Torque and drive-output evaluation |
| RMS current | Effective current value used for heating calculations | Copper loss and continuous thermal evaluation |
| Waveform peak current | Maximum instantaneous value of the specified waveform | Waveform conversion and instantaneous limits |
| Overload current rating | Current permitted for a defined overload interval | Starting, acceleration and transient-load evaluation |
For a sinusoidal current waveform:
Ipeak = √2 × Irms
Do not apply this conversion automatically to six-step or other non-sinusoidal current waveforms.
Also distinguish the peak of a waveform from a short-duration overload rating. A datasheet may use the word “peak” for either concept.
When comparing a motor and controller, ask whether both current ratings use the same definition and whether the controller can provide the required current for the required duration.
5. Read Rated and Peak Torque Correctly
Continuous and peak ratings are not interchangeable. Neither should be interpreted without the stated operating conditions.
| Parameter | What It Means | What to Verify |
|---|---|---|
| Rated or continuous torque | Torque permitted under the specified rated conditions | Speed, ambient temperature, mounting, cooling and duty |
| Rated or continuous current | Current associated with the stated continuous conditions | Current convention and thermal limits |
| Peak torque | Short-duration torque under specified conditions | Duration, speed, repetition and controller capability |
| Peak or overload current | Short-duration current under specified conditions | Duration, recovery time and initial temperature |
| Stall torque or stall current | Torque or current at zero speed under the stated test conditions | Whether the value is controlled, transient or continuously permissible |
Stall current is not automatically the same as permitted peak current. A theoretical locked-rotor current can exceed both motor and controller limits.
Start with the continuous torque required at the operating speed. Then verify starting, acceleration, reversing and overload requirements.
For repeated start-stop cycles, RMS torque can be a useful initial thermal-sizing indicator when torque is proportional to current:
Trms = √[(T1²t1 + T2²t2 + ... + Tn²tn) ÷ total cycle time]
This is a screening method, not a substitute for checking speed-dependent losses, cooling, peak limits and the actual thermal response.
6. Decode Resistance, Inductance, No-Load Current and Efficiency
6.1 Winding Resistance
Resistance is needed to estimate copper loss. Confirm whether the stated value is per phase or measured between motor terminals, and note the measurement temperature.
For a balanced three-phase motor with equal phase resistances:
Pcu = 3 × Iphase,rms² × Rphase
For a star-connected winding, a DC measurement between two terminals gives twice the individual phase resistance:
Rline-line = 2 × Rphase
With that resistance definition and RMS line current:
Pcu = 1.5 × Iline,rms² × Rline-line
Do not mix the 1.5 factor with a resistance explicitly defined as the individual phase resistance.
At a fixed resistance, doubling RMS current quadruples copper loss. Resistance also changes with winding temperature, so a cold-resistance calculation is not a complete hot-running loss prediction.
Lower resistance alone does not prove higher efficiency. Compare the complete operating point and all relevant losses.
6.2 Phase Inductance
Inductance influences current ripple and current-control behavior. Its measurement may depend on terminal arrangement, test frequency and rotor position.
For controller evaluation, provide the resistance and inductance definitions along with the intended current-control and PWM settings. A controller suitable for one winding is not automatically suitable for another motor with the same rated voltage.
6.3 No-Load Current
No-load current is measured while the motor runs without an external shaft load at a stated voltage and speed.
It reflects the power needed to overcome internal losses, but its interpretation depends on whether it is measured at the DC input or in the motor phases and whether controller consumption is included.
Subtracting no-load current can be useful in some consistent equivalent models. It is not a universal correction for every BLDC torque calculation.
A change in no-load current is a reason to investigate the motor, drive and test conditions, not a diagnosis of a specific fault by itself.
6.4 Efficiency
Efficiency must be stated at an operating point and with a defined measurement boundary:
- Motor efficiency compares shaft output with electrical power delivered to the motor.
- Drive-system efficiency compares shaft output with input power to the controller.
- Geared-system efficiency also includes gearbox losses when output is measured after the gearbox.
A maximum efficiency figure does not describe efficiency at every speed and torque.
For a stable DC supply, average input power may be approximated by bus voltage multiplied by average bus current. Where voltage and current vary significantly, use an appropriate power measurement.
7. Check Power, Inertia, Thermal Limits and Mechanical Interfaces
7.1 Rated Torque, Speed and Power
Shaft torque, rotational speed and mechanical output power are linked:
Pout [W] = Tshaft [N·m] × n [RPM] ÷ 9.5493
Equivalently:
Pout [kW] = Tshaft [N·m] × n [RPM] ÷ 9549.3
When these values describe the same rated operating point, they should be consistent within rounding and stated tolerances. If they are not, ask whether the figures refer to different conditions or whether power is defined differently.
Rated motor power commonly refers to shaft output, but verify the manufacturer’s definition rather than assuming every product page uses the term consistently.
7.2 Torque-Speed Curve and Maximum Speed
One rated point does not describe the full operating envelope. Request continuous and intermittent torque-speed information for the intended supply and controller.
Achievable speed depends on voltage headroom, winding properties, load, current limits and control strategy. A simple equivalent model may use n ≈ KV × (V − IR), but real three-phase drive evaluation also involves inductive voltage, modulation and controller operation.
Do not use a simplified KV calculation to exceed the motor’s mechanical speed limit.
7.3 Rotor Inertia and Acceleration
Rotor inertia describes resistance to angular acceleration. For a simple rigid system:
Tacc = Jtotal × α
α = Δω ÷ Δt
Use total inertia referred to the motor shaft, not rotor inertia alone. Include the coupling, transmission and reflected load inertia where applicable.
Required motor torque also includes the driven load and losses. A gearbox changes both the torque-speed relationship and the load inertia seen by the motor.
7.4 Thermal Resistance and Duty Cycle
A simplified steady-state thermal model uses:
Temperature rise ≈ heat loss × thermal resistance
The result is meaningful only when the loss distribution, thermal path, mounting and cooling conditions match the stated thermal model.
Short-duration operation also depends on thermal capacitance and time constants. Thermal resistance alone cannot determine a safe overload duration.
Intermittent operation may permit higher short-term loading, but the allowable level depends on run time, rest time, starting temperature and repetition.
7.5 Insulation Class and Other Temperature Limits
Common insulation thermal classes include B (130 °C), F (155 °C) and H (180 °C).
These class temperatures are not permission to operate every motor component at that temperature. Magnets, bearings, grease, adhesives, electronics and feedback devices may impose lower limits.
See Boyang’s BLDC insulation classes guide for related background. Confirm the applicable limits and test requirements for the specific configuration.
7.6 Mechanical and Environmental Requirements
Check:
- Housing diameter and overall length.
- Flange, pilot and mounting-hole arrangement.
- Shaft diameter, extension, keyway, flat or thread.
- Permissible radial and axial loads.
- Cable exit, connector position and pinout.
- Feedback, brake and gearbox interfaces.
- Ambient temperature and environmental exposure.
- Protection rating for the final configured assembly.
Boyang has supplied custom IP67 and IP68 motor configurations. These ratings apply to the specified configuration, not automatically to every motor in the same frame-size range.
8. Worked Example: Torque, Copper Loss and System Efficiency
The following example uses hypothetical values to demonstrate the reading process. It is not a Boyang model specification.
The motor uses a star-connected winding and a compatible sinusoidal drive. Kt is defined per RMS phase current.
| Parameter | Value | Definition |
|---|---|---|
| DC bus voltage | 24 V DC | Controller supply voltage |
| Torque constant | 0.10 N·m/Arms | Electromagnetic torque per RMS phase current |
| Phase current | 3 Arms | Current in each motor phase |
| Line-to-line resistance | 0.50 Ω | DC terminal measurement at the stated temperature |
| Measured shaft speed | 2,000 RPM | Operating speed under load |
| Measured shaft torque | 0.28 N·m | Useful mechanical output torque |
| Measured average DC input current | 3.0 A | Controller input current at this operating point |
Step 1: Estimate Electromagnetic Torque
Tem ≈ Kt × Iphase,rms = 0.10 × 3 = 0.30 N·m
The measured shaft torque is 0.28 N·m. Electromagnetic torque and useful shaft torque are not assumed to be identical.
Step 2: Calculate Copper Loss
For the star-connected winding:
Rphase = 0.50 ÷ 2 = 0.25 Ω
Pcu = 3 × 3² × 0.25 = 6.75 W
This is the copper-loss estimate at the resistance measurement temperature. It excludes magnetic, mechanical and controller losses.
Step 3: Calculate Shaft Output Power
Pout = 0.28 × 2000 ÷ 9.5493 ≈ 58.6 W
Step 4: Calculate DC Input Power
For the stable 24 V DC supply in this example:
Pin ≈ 24 × 3.0 = 72 W
The DC input current is a separately measured quantity. Its numerical equality to the phase RMS current in this example is not a general relationship.
Step 5: Calculate Drive-System Efficiency
ηsystem = 58.6 ÷ 72 × 100% ≈ 81.4%
This result includes controller losses because the electrical measurement is taken at the controller’s DC input.
Total drive-system loss is approximately 13.4 W. The 6.75 W copper-loss estimate accounts for only part of that total.
What This Example Does Not Establish
These calculations do not prove that the operating point is continuously permissible. That requires checking the continuous operating envelope and thermal conditions.
They also do not derive loaded speed from bus voltage alone. The example uses measured speed and torque to avoid treating an incomplete motor model as a performance guarantee.
9. Apply the Datasheet to Your Equipment
Different machines place different demands on the same motor. Use the equipment’s operating profile to decide which datasheet parameters need the most attention.
| Equipment | Parameters to Prioritize | Information to Provide |
|---|---|---|
| Laboratory automation and sample-handling equipment | Low-speed operation, feedback, inertia and peak torque | Motion profile, positioning needs and start-stop frequency |
| Medical equipment mechanisms | Required operating point, temperature, noise and interfaces | Installation space, operating cycle and project validation requirements |
| Metering pumps and fluid-transfer equipment | Torque-speed requirements, starting load and duty | Pump type, pressure conditions and required operating range |
| Conveyors and material-handling equipment | Continuous torque, acceleration torque and gearbox output | Load, belt speed, transmission ratio and starting conditions |
| Agricultural machinery | Load variation, peak torque, interfaces and protection | Motor function, field exposure, chemicals and cleaning conditions |
| Outdoor actuators and solar trackers | Output torque, feedback, brake requirements and protection | Movement cycle, holding requirement and environmental conditions |
| Fans and ventilation equipment | Speed range, load curve, efficiency and continuous thermal performance | Required airflow-related operating points and installation conditions |
These are engineering evaluation categories, not a declaration that every reference motor is approved for every application.
Boyang has supplied 57 mm, 80 mm and 90 mm motors for customers’ agricultural machinery. For new equipment, the final motor is defined by the project rather than by frame size alone.
10. BLDC Motor Datasheet and RFQ Checklist
| Category | Fields to Confirm |
|---|---|
| Operating requirement | Continuous torque, speed range, peak torque, duration and duty cycle |
| Supply and controller | Voltage range, controller model, current limits and control method |
| Motor constants | KV, Ke and Kt with units, waveform and voltage/current definitions |
| Electrical characteristics | Resistance, inductance, connection type and measurement conditions |
| Performance | Rated operating point, torque-speed curve, no-load data and efficiency boundary |
| Mechanical interfaces | Flange, shaft, overall dimensions, load limits, cable and connector |
| Thermal conditions | Ambient temperature, mounting, cooling and temperature limits |
| Environment | Dust, water, chemicals, cleaning and required protection conditions |
| Feedback and accessories | Hall signals, encoder, brake, gearbox and integrated-drive requirements |
| Validation | Prototype tests, documentation and customer acceptance criteria |
You do not need to know every motor constant before making an inquiry. If the datasheet is incomplete, send your operating requirements and the available information so that the missing definitions can be identified.
For a replacement project, provide the original nameplate, datasheet, drawing, controller information or physical sample. See: What Specifications Must Match When Replacing a BLDC Motor?
11. Boyang Reference Platforms for Custom OEM Projects
Boyang’s product pages provide reference platforms for discussing motor performance and integration. They are not a requirement to select an unchanged catalog configuration.
- Brushless DC motor range — starting point for winding, performance and mechanical evaluation.
- 57 mm BLDC motor — reference platform for compact OEM motor projects.
- 80 mm BLDC motor — reference platform for performance and installation evaluation.
- 90 mm round BLDC motor — round motor platform for project-specific integration.
- Motor controllers — evaluate voltage, current definitions, feedback and control compatibility.
- Planetary gearboxes — evaluate output torque, output speed, mounting and reflected load.
Custom requirements may include flange and shaft dimensions, dual shafts, feedback, encoders, brakes, sensorless control, integrated controllers and project-specific protection. Final options and supporting documentation are confirmed for the configuration under development.
12. Frequently Asked Questions
What should I read first on a BLDC motor datasheet?
Start with the rated torque, rated speed, supply voltage and duty conditions. Then check whether the motor can meet your continuous and peak-load requirements with the intended controller and cooling.
Is Ke always numerically equal to Kt?
Not directly across all published BLDC datasheets. The numerical equality applies under consistent SI definitions. Published constants may use different phase, line-to-line, RMS, peak and commutation conventions that require additional conversion.
How do I convert KV to Kt?
In a compatible ideal equivalent-motor convention, Kt [N·m/A] = 9.5493 ÷ KV [RPM/V]. Before using this result with a controller’s current limit, confirm that the motor and controller use matching definitions.
What does KV mean, and is it the same as kV?
KV is commonly used for a motor speed constant expressed in RPM/V. It is not the electrical unit kV, meaning kilovolts. Motor KV does not specify rated power or continuous torque.
Does a higher KV motor produce more torque?
Not by itself. Under comparable definitions, higher KV corresponds to lower torque per amp. Total usable torque also depends on permissible current, motor construction and thermal conditions.
Can I calculate torque using the DC supply current?
Only when the torque constant and current definition support that calculation. A Kt stated per RMS phase current should not be multiplied by DC bus current without a valid conversion or model.
What is the difference between rated current and peak current?
Rated current relates to the specified continuous operating conditions. Peak or overload current is permitted under defined transient conditions. Confirm its duration, repetition, current convention and initial thermal conditions.
Is peak current the same as stall current?
Not necessarily. Stall describes zero-speed operation, while a peak rating describes a permitted current or torque condition. The datasheet must explain whether the stall figure is controlled, transient or continuously permissible.
How do I calculate BLDC winding copper loss?
With equal phase resistances, use Pcu = 3 × Iphase,rms² × Rphase. If using terminal resistance instead, first confirm winding connection and the applicable resistance conversion.
Can voltage, KV and resistance predict loaded speed exactly?
No. They can support an estimate under a defined simplified model. Actual loaded speed also depends on current, inductance, control, voltage headroom, losses and operating limits. Use performance curves or testing for application validation.
Is rated power the same as electrical input power?
Usually, rated motor power refers to shaft output, but confirm the definition. Electrical input is higher because of losses. Motor-only and controller-plus-motor measurements have different efficiency boundaries.
Does the insulation class define the motor’s operating temperature?
It describes the insulation system’s thermal class. Other components may have lower temperature limits. Confirm the permitted winding, housing, bearing and electronics temperatures for the actual motor.
Can Boyang customize a motor if the reference datasheet does not match my machine?
Yes. Reference models are starting points for OEM evaluation. Send the required operating point, installation drawing, controller details, feedback requirements and environment so that the necessary customization can be evaluated.
13. Request a Custom BLDC Motor Evaluation
A useful motor request describes the machine requirement, not only a wattage:
We need this continuous torque at this speed, with this peak load for this duration, using this supply and controller, inside this installation space and environment.
Send Boyang your equipment type, voltage range, torque-speed requirement, duty cycle, mounting drawing and control interfaces.
If you are replacing an existing motor, also send its datasheet, nameplate, drawing, controller details or sample information.
Boyang will evaluate a suitable reference platform and the mechanical, electrical and control customization needed for your equipment. Final specifications, interfaces and validation requirements are confirmed for the project.
Contact Boyang Motor
Email: [email protected]
Website: www.boyangmotor.com
Products
Brushless Motor
16mm Brushless
24mm Brushless
28mm Brushless
30mm Brushless
57mm Brushless
60mm BLDC
92mm BLDC
150mm BLDC
DC Brush Motor
30mm Brush
36mm Brush
38mm Brush
42mm Brush
52mm Brush
80mm Brush
90mm Brush
Brushless Gear Pump
20 Gear Pump
30 Gear Pump
60 Gear Pump
100 Gear Pump
150 Gear Pump
200 Gear Pump
350 Gear Pump
Brushless Fan/Blower
25 Cross Flow Fan
30 Cross Flow Fan
40 Cross Flow Fan
50 Cross Flow Fan
60 Cross Flow Fan
90 Cross Flow Fan
120 Cross Flow Fan
Servo Motor
40 Servo Motor
60 Servo Motor
80 Servo Motor
110 Servo Motor
130 Servo Motor
180 Servo Motor
Planerary Gearbox
22 Planetary Gear
28 Planetary Gear
32 Planetary Gear
36 Planetary Gear
42 Planetary Gear
60 Planetary Gear
90 Planetary Gear
120 Planetary Gear
Motor Controller
3A Integrated Controller
5A Integrated Controller
8A Integrated Controller
3A BLDC Controller
15A BLDC Controller
50A BLDC Controller
AC BLDC Driver
Panel Driver
Custom Parts
Speed Regulating
Dissipating Housing
Connector
Motor Bracket
Custom Solutions