How to Select a Micro Magnetic Gear Pump: Flow, Pressure, Speed & Materials
How to Select a Micro Magnetic Gear Pump: Flow, Pressure, RPM & Materials
Selecting the right micro magnetic gear pump requires more than looking at the maximum flow rate. Engineers should consider flow, differential pressure, RPM, fluid viscosity, temperature, materials and motor torque together.
For OEM applications, the goal is to find a pump that can deliver the required flow at the required pressure and with the actual working fluid.
Quick Answer
To select a micro magnetic gear pump, follow these steps:
-
Define the required flow rate.
-
Determine the required differential pressure.
-
Select the appropriate pump displacement and RPM.
-
Check fluid viscosity and temperature.
-
Confirm material compatibility.
-
Determine whether self-priming is required.
-
Match the pump with the BLDC motor.
-
Verify the complete operating point with pump performance data.
The basic relationship is:
Actual Flow ≈ Displacement × RPM × Volumetric Efficiency
For detailed flow calculations, see:
https://www.boyangmotor.com/news/how-to-calculate-micro-gear-pump-flow-rate/
1. Start With Required Flow Rate
The first question is:
How much fluid does the system need?
Define the:
-
Minimum flow
-
Normal operating flow
-
Maximum flow
For example:
| Requirement | Example |
|---|---|
| Minimum flow | 0.5 L/min |
| Normal flow | 1.5 L/min |
| Maximum flow | 2.0 L/min |
Micro gear pumps are positive-displacement pumps, so flow is closely related to pump displacement and RPM.
Basic Formula
Qₜ = V × N
For L/min:
Qₜ = V × RPM ÷ 1000
Where:
-
Qₜ = theoretical flow in L/min
-
V = displacement in ml/rev
-
RPM = pump speed
For example:
A 1.0 ml/rev pump running at 2,000 RPM has a theoretical flow of:
1.0 × 2,000 ÷ 1,000 = 2.0 L/min
Actual flow will be lower or higher depending on operating conditions and pump design.
2. Check Differential Pressure
Flow rate alone is not enough.
The pump must deliver the required flow against the system's resistance.
Differential pressure is:
ΔP = Outlet Pressure − Inlet Pressure
Pressure losses may come from:
-
Pipes
-
Filters
-
Valves
-
Heat exchangers
-
Nozzles
-
Fittings
-
System backpressure
For example, a pump that delivers 3 L/min at low pressure may deliver considerably less at 10 bar differential pressure.
See our detailed guide:
https://www.boyangmotor.com/news/gear-pump-pressure-differential-vs-system-pressure/
Important:
Differential pressure and system withstand pressure are not the same specification.
A pump designed to withstand 40 bar system pressure should not automatically be considered capable of delivering its rated flow at 40 bar differential pressure.
3. Select Pump Displacement and RPM
Pump displacement determines how much fluid is theoretically moved per revolution.
Typical micro magnetic gear pump displacement options include approximately:
0.2–3.5 ml/rev
The required displacement depends on the desired flow and operating speed.
| Displacement | At 2,000 RPM* |
|---|---|
| 0.2 ml/rev | 0.40 L/min |
| 0.5 ml/rev | 1.00 L/min |
| 1.0 ml/rev | 2.00 L/min |
| 1.5 ml/rev | 3.00 L/min |
| 2.0 ml/rev | 4.00 L/min |
*Theoretical flow before considering volumetric efficiency and pressure effects.
For variable-flow applications, a BLDC motor provides a major advantage because pump speed can be adjusted electronically.
4. Consider Fluid Viscosity
Viscosity has a significant effect on micro gear pump performance.
Low-viscosity fluids
Very low viscosity can increase internal leakage and reduce volumetric efficiency.
High-viscosity fluids
Higher viscosity generally increases:
-
Motor torque
-
Starting torque
-
Current
-
Heat generation
-
Pressure losses
Therefore, the viscosity should always be specified at the actual operating temperature.
More information:
https://www.boyangmotor.com/news/micro-gear-pump-viscosity-flow-pressure-motor-torque/
5. Check Fluid Temperature
Temperature affects both the fluid and pump materials.
As temperature changes, viscosity, internal clearances and material properties can also change.
When selecting a pump, specify:
-
Minimum fluid temperature
-
Normal operating temperature
-
Maximum fluid temperature
-
Ambient temperature
Do not select a pump based only on its maximum temperature specification. The combination of temperature + pressure + viscosity + RPM must be considered.
6. Select the Correct Materials
Material compatibility is especially important for chemical, medical and laboratory applications.
Depending on the pump configuration, materials may include:
-
SS316 / 316L stainless steel
-
PEEK
-
Ceramic
-
Hastelloy
-
PPS
-
PTFE
-
FKM
-
EPDM
The complete wetted path must be considered, including:
Housing + Gears + Shaft + Bearings + O-rings
For a detailed comparison of PEEK and ceramic components:
https://www.boyangmotor.com/news/peek-vs-ceramic-micro-magnetic-gear-pumps/
For chemical compatibility:
7. Do You Need Self-Priming?
If the pump needs to draw fluid from a reservoir or operate with air in the inlet line, self-priming capability becomes important.
Consider:
-
Suction lift
-
Inlet tubing length
-
Fluid viscosity
-
Startup speed
-
Air handling
-
Dry-running conditions
Self-priming does not mean unlimited dry running. Actual performance depends on the pump configuration and operating conditions.
Read more:
https://www.boyangmotor.com/news/self-priming-micro-gear-pumps-suction-lift-dry-running/
8. Match the Gear Pump With the BLDC Motor
For a brushless gear pump, pump and motor selection should be performed together.
The basic relationship is:
Required Flow → Pump RPM → Pump Torque → Motor Selection
When differential pressure increases, the pump generally requires more torque.
The motor should therefore be selected according to:
-
Voltage
-
RPM
-
Continuous torque
-
Peak torque
-
Current
-
Cooling
-
Hall or sensorless control
-
Duty cycle
For OEM applications, matching the BLDC motor to the actual pump operating point is essential.
See:
https://www.boyangmotor.com/news/how-to-match-a-bldc-motor-with-a-micro-gear-pump/
9. Example: Selecting a Micro Magnetic Gear Pump
Suppose an OEM cooling system requires:
| Parameter | Requirement |
|---|---|
| Flow | 2.0 L/min |
| Differential pressure | 10 bar |
| Fluid | Coolant |
| Temperature | 60°C |
| Voltage | 24 VDC |
| Target speed | 2,000 RPM |
| Duty | Continuous |
Step 1 — Calculate displacement
V = Flow × 1000 ÷ RPM
V = 2.0 × 1000 ÷ 2,000
V = 1.0 ml/rev
A 1.0 ml/rev pump is therefore a reasonable starting point.
Step 2 — Verify pressure
The pump must be able to provide approximately 2.0 L/min at 10 bar differential pressure.
Step 3 — Check viscosity and temperature
Confirm the coolant's viscosity at 60°C.
Step 4 — Check materials
Verify compatibility of the coolant with the housing, gears, shaft, bearings and seals.
Step 5 — Select the motor
The BLDC motor must provide sufficient continuous torque at 2,000 RPM and the required pressure.
The final selection should then be verified using actual pump performance data.
10. Common Selection Mistakes
Choosing by maximum flow
Always consider:
Flow at the required pressure
rather than maximum catalog flow.
Ignoring viscosity
The same pump can behave very differently with water and high-viscosity fluids.
Confusing pressure specifications
Differential pressure ≠ system withstand pressure
Ignoring motor torque
High pressure and high viscosity can significantly increase motor load.
Selecting materials only by the housing
All wetted components must be chemically compatible.
Micro Magnetic Gear Pump Selection Checklist
Before requesting a quotation, provide:
| Parameter | Required Information |
|---|---|
| Flow | L/min or ml/min |
| Differential pressure | bar / MPa |
| Fluid | Fluid name |
| Viscosity | cP or mPa·s |
| Temperature | °C |
| Voltage | VDC |
| RPM | Required speed |
| Duty cycle | Continuous / intermittent |
| Self-priming | Yes / No |
| Materials | Required material |
| Port | Standard / Custom |
| Service life | Required hours |
The more complete the information, the more accurately the pump and BLDC motor can be selected.
Conclusion
The best micro magnetic gear pump is not necessarily the pump with the highest flow or pressure rating.
A correct selection should match:
Flow + Differential Pressure + RPM + Viscosity + Temperature + Materials + Motor Torque
For OEM systems, the pump and BLDC motor should be evaluated as one complete fluid-handling system.
Boyang Motor offers micro magnetic gear pump configurations covering approximately 0.2–3.5 ml/rev displacement, with different flow, pressure, material and motor configurations for industrial, medical, chemical, cooling and precision dosing applications.
Related Engineering Guides
Flow Rate Calculation:
https://www.boyangmotor.com/news/how-to-calculate-micro-gear-pump-flow-rate/
Pressure Selection:
https://www.boyangmotor.com/news/gear-pump-pressure-differential-vs-system-pressure/
Viscosity Selection:
https://www.boyangmotor.com/news/micro-gear-pump-viscosity-flow-pressure-motor-torque/
Self-Priming:
https://www.boyangmotor.com/news/self-priming-micro-gear-pumps-suction-lift-dry-running/
BLDC Motor Matching:
https://www.boyangmotor.com/news/how-to-match-a-bldc-motor-with-a-micro-gear-pump/
Micro Magnetic Gear Pump Products:
https://www.boyangmotor.com/brushless-gear-pump/
Products
Brushless Motor
16mm Brushless
24mm Brushless
28mm Brushless
30mm Brushless
57mm Brushless
60mm BLDC
92mm BLDC
150mm BLDC
DC Brush Motor
30mm Brush
36mm Brush
38mm Brush
42mm Brush
52mm Brush
80mm Brush
90mm Brush
Brushless Gear Pump
20 Gear Pump
30 Gear Pump
60 Gear Pump
100 Gear Pump
150 Gear Pump
200 Gear Pump
350 Gear Pump
Brushless Fan/Blower
25 Cross Flow Fan
30 Cross Flow Fan
40 Cross Flow Fan
50 Cross Flow Fan
60 Cross Flow Fan
90 Cross Flow Fan
120 Cross Flow Fan
Servo Motor
40 Servo Motor
60 Servo Motor
80 Servo Motor
110 Servo Motor
130 Servo Motor
180 Servo Motor
Planerary Gearbox
22 Planetary Gear
28 Planetary Gear
32 Planetary Gear
36 Planetary Gear
42 Planetary Gear
60 Planetary Gear
90 Planetary Gear
120 Planetary Gear
Motor Controller
3A Integrated Controller
5A Integrated Controller
8A Integrated Controller
3A BLDC Controller
15A BLDC Controller
50A BLDC Controller
AC BLDC Driver
Panel Driver
Custom Parts
Speed Regulating
Dissipating Housing
Connector
Motor Bracket
Custom Solutions