Selecting the right micro magnetic gear pump requires more than looking at the maximum flow rate. Engineers should consider flow, differential pressure, RPM, fluid viscosity, temperature, materials and motor torque together.

For OEM applications, the goal is to find a pump that can deliver the required flow at the required pressure and with the actual working fluid.

Quick Answer

To select a micro magnetic gear pump, follow these steps:

  1. Define the required flow rate.

  2. Determine the required differential pressure.

  3. Select the appropriate pump displacement and RPM.

  4. Check fluid viscosity and temperature.

  5. Confirm material compatibility.

  6. Determine whether self-priming is required.

  7. Match the pump with the BLDC motor.

  8. Verify the complete operating point with pump performance data.

The basic relationship is:

Actual Flow ≈ Displacement × RPM × Volumetric Efficiency

For detailed flow calculations, see:

https://www.boyangmotor.com/news/how-to-calculate-micro-gear-pump-flow-rate/


1. Start With Required Flow Rate

The first question is:

How much fluid does the system need?

Define the:

  • Minimum flow

  • Normal operating flow

  • Maximum flow

For example:

Requirement Example
Minimum flow 0.5 L/min
Normal flow 1.5 L/min
Maximum flow 2.0 L/min

Micro gear pumps are positive-displacement pumps, so flow is closely related to pump displacement and RPM.

Basic Formula

Qₜ = V × N

For L/min:

Qₜ = V × RPM ÷ 1000

Where:

  • Qₜ = theoretical flow in L/min

  • V = displacement in ml/rev

  • RPM = pump speed

For example:

A 1.0 ml/rev pump running at 2,000 RPM has a theoretical flow of:

1.0 × 2,000 ÷ 1,000 = 2.0 L/min

Actual flow will be lower or higher depending on operating conditions and pump design.


2. Check Differential Pressure

Flow rate alone is not enough.

The pump must deliver the required flow against the system's resistance.

Differential pressure is:

ΔP = Outlet Pressure − Inlet Pressure

Pressure losses may come from:

  • Pipes

  • Filters

  • Valves

  • Heat exchangers

  • Nozzles

  • Fittings

  • System backpressure

For example, a pump that delivers 3 L/min at low pressure may deliver considerably less at 10 bar differential pressure.

See our detailed guide:

https://www.boyangmotor.com/news/gear-pump-pressure-differential-vs-system-pressure/

Important:

Differential pressure and system withstand pressure are not the same specification.

A pump designed to withstand 40 bar system pressure should not automatically be considered capable of delivering its rated flow at 40 bar differential pressure.


3. Select Pump Displacement and RPM

Pump displacement determines how much fluid is theoretically moved per revolution.

Typical micro magnetic gear pump displacement options include approximately:

0.2–3.5 ml/rev

The required displacement depends on the desired flow and operating speed.

Displacement At 2,000 RPM*
0.2 ml/rev 0.40 L/min
0.5 ml/rev 1.00 L/min
1.0 ml/rev 2.00 L/min
1.5 ml/rev 3.00 L/min
2.0 ml/rev 4.00 L/min

*Theoretical flow before considering volumetric efficiency and pressure effects.

For variable-flow applications, a BLDC motor provides a major advantage because pump speed can be adjusted electronically.


4. Consider Fluid Viscosity

Viscosity has a significant effect on micro gear pump performance.

Low-viscosity fluids

Very low viscosity can increase internal leakage and reduce volumetric efficiency.

High-viscosity fluids

Higher viscosity generally increases:

  • Motor torque

  • Starting torque

  • Current

  • Heat generation

  • Pressure losses

Therefore, the viscosity should always be specified at the actual operating temperature.

More information:

https://www.boyangmotor.com/news/micro-gear-pump-viscosity-flow-pressure-motor-torque/


5. Check Fluid Temperature

Temperature affects both the fluid and pump materials.

As temperature changes, viscosity, internal clearances and material properties can also change.

When selecting a pump, specify:

  • Minimum fluid temperature

  • Normal operating temperature

  • Maximum fluid temperature

  • Ambient temperature

Do not select a pump based only on its maximum temperature specification. The combination of temperature + pressure + viscosity + RPM must be considered.


6. Select the Correct Materials

Material compatibility is especially important for chemical, medical and laboratory applications.

Depending on the pump configuration, materials may include:

  • SS316 / 316L stainless steel

  • PEEK

  • Ceramic

  • Hastelloy

  • PPS

  • PTFE

  • FKM

  • EPDM

The complete wetted path must be considered, including:

Housing + Gears + Shaft + Bearings + O-rings

For a detailed comparison of PEEK and ceramic components:

https://www.boyangmotor.com/news/peek-vs-ceramic-micro-magnetic-gear-pumps/

For chemical compatibility:

https://www.boyangmotor.com/news/chemical-compatibility-of-magnetic-drive-micro-gear-pumps-ss316-hastelloy-special-plastics-selection-guide/


7. Do You Need Self-Priming?

If the pump needs to draw fluid from a reservoir or operate with air in the inlet line, self-priming capability becomes important.

Consider:

  • Suction lift

  • Inlet tubing length

  • Fluid viscosity

  • Startup speed

  • Air handling

  • Dry-running conditions

Self-priming does not mean unlimited dry running. Actual performance depends on the pump configuration and operating conditions.

Read more:

https://www.boyangmotor.com/news/self-priming-micro-gear-pumps-suction-lift-dry-running/


8. Match the Gear Pump With the BLDC Motor

For a brushless gear pump, pump and motor selection should be performed together.

The basic relationship is:

Required Flow → Pump RPM → Pump Torque → Motor Selection

When differential pressure increases, the pump generally requires more torque.

The motor should therefore be selected according to:

  • Voltage

  • RPM

  • Continuous torque

  • Peak torque

  • Current

  • Cooling

  • Hall or sensorless control

  • Duty cycle

For OEM applications, matching the BLDC motor to the actual pump operating point is essential.

See:

https://www.boyangmotor.com/news/how-to-match-a-bldc-motor-with-a-micro-gear-pump/


9. Example: Selecting a Micro Magnetic Gear Pump

Suppose an OEM cooling system requires:

Parameter Requirement
Flow 2.0 L/min
Differential pressure 10 bar
Fluid Coolant
Temperature 60°C
Voltage 24 VDC
Target speed 2,000 RPM
Duty Continuous

Step 1 — Calculate displacement

V = Flow × 1000 ÷ RPM

V = 2.0 × 1000 ÷ 2,000

V = 1.0 ml/rev

A 1.0 ml/rev pump is therefore a reasonable starting point.

Step 2 — Verify pressure

The pump must be able to provide approximately 2.0 L/min at 10 bar differential pressure.

Step 3 — Check viscosity and temperature

Confirm the coolant's viscosity at 60°C.

Step 4 — Check materials

Verify compatibility of the coolant with the housing, gears, shaft, bearings and seals.

Step 5 — Select the motor

The BLDC motor must provide sufficient continuous torque at 2,000 RPM and the required pressure.

The final selection should then be verified using actual pump performance data.


10. Common Selection Mistakes

Choosing by maximum flow

Always consider:

Flow at the required pressure

rather than maximum catalog flow.

Ignoring viscosity

The same pump can behave very differently with water and high-viscosity fluids.

Confusing pressure specifications

Differential pressure ≠ system withstand pressure

Ignoring motor torque

High pressure and high viscosity can significantly increase motor load.

Selecting materials only by the housing

All wetted components must be chemically compatible.


Micro Magnetic Gear Pump Selection Checklist

Before requesting a quotation, provide:

Parameter Required Information
Flow L/min or ml/min
Differential pressure bar / MPa
Fluid Fluid name
Viscosity cP or mPa·s
Temperature °C
Voltage VDC
RPM Required speed
Duty cycle Continuous / intermittent
Self-priming Yes / No
Materials Required material
Port Standard / Custom
Service life Required hours

The more complete the information, the more accurately the pump and BLDC motor can be selected.


Conclusion

The best micro magnetic gear pump is not necessarily the pump with the highest flow or pressure rating.

A correct selection should match:

Flow + Differential Pressure + RPM + Viscosity + Temperature + Materials + Motor Torque

For OEM systems, the pump and BLDC motor should be evaluated as one complete fluid-handling system.

Boyang Motor offers micro magnetic gear pump configurations covering approximately 0.2–3.5 ml/rev displacement, with different flow, pressure, material and motor configurations for industrial, medical, chemical, cooling and precision dosing applications.

Related Engineering Guides

Flow Rate Calculation:
https://www.boyangmotor.com/news/how-to-calculate-micro-gear-pump-flow-rate/

Pressure Selection:
https://www.boyangmotor.com/news/gear-pump-pressure-differential-vs-system-pressure/

Viscosity Selection:
https://www.boyangmotor.com/news/micro-gear-pump-viscosity-flow-pressure-motor-torque/

Self-Priming:
https://www.boyangmotor.com/news/self-priming-micro-gear-pumps-suction-lift-dry-running/

BLDC Motor Matching:
https://www.boyangmotor.com/news/how-to-match-a-bldc-motor-with-a-micro-gear-pump/

Micro Magnetic Gear Pump Products:
https://www.boyangmotor.com/brushless-gear-pump/