Micro Gear Pumps for Analytical & Laboratory Instruments
Brushless DC Gear Pumps

Micro Gear Pumps for Analytical & Laboratory Instruments

2026-09-06

The Engineer Starts With the Fluid Circuit

When selecting a pump for laboratory equipment, the first question is rarely:

“Which pump has the highest flow?”

The more useful question is:

What flow must the instrument maintain at the actual pressure, temperature and fluid condition?

Analytical instruments can require very small fluid volumes, but the pump may still need to overcome:

  • Tubing resistance

  • Filters

  • Valves

  • Reaction chambers

  • Sampling lines

  • Elevation differences

A micro gear pump can provide compact positive-displacement fluid delivery for these systems.

1. Common Applications

Micro magnetic gear pumps can be evaluated for:

  • Reagent delivery

  • Sample preparation

  • Buffer circulation

  • Cleaning circuits

  • Automated liquid handling

  • Sampling

  • Laboratory coating

  • Flushing

  • Compact cooling loops

Different applications require different pump configurations.

2. Current Product Range

The current BYMP family includes:

Series Displacement Options Maximum Listed Flow
BYMP020 0.2 / 0.39 / 0.6 / 0.7 ml/rev Up to 2.2 L/min
BYMP030 1.0 / 1.2 / 1.7 / 1.9 ml/rev Up to 6.0 L/min
BYMP060 2.4 / 3.5 ml/rev Up to 10.5 L/min
BYMP070 4 / 6 / 9 / 12 / 17 ml/rev Up to 55 L/min
BYMP100 26 ml/rev Up to 65 L/min

For many laboratory fluid circuits, the appropriate selection will be within the smaller displacement range.

The larger configurations can be considered for flushing, circulation and higher-volume transfer.

3. Flow Calculation

Theoretical flow can be estimated using:

Flow (L/min) = Displacement (ml/rev) × RPM / 1000

For example:

1.0 ml/rev × 2,000 rpm = 2 L/min theoretical flow

Actual flow depends on pressure, viscosity, temperature, speed and internal leakage.

Therefore, the calculation is a starting point rather than a guaranteed flow value.

4. Differential Pressure

Laboratory tubing may look small, but pressure loss can become significant when:

  • Tubing is long

  • Internal diameter is small

  • Fluid viscosity is high

  • Filters are fine

  • Valves create restriction

The pump must therefore be evaluated at the required flow and actual differential pressure.

Current BYMP configurations can provide approximately 20–30 bar differential pressure for water delivery, depending on model/configuration.

Some configurations also provide 25–40 bar system withstand pressure.

These are different specifications.

5. Materials and Chemical Compatibility

Laboratory fluids can include:

  • Reagents

  • Solvents

  • Buffers

  • Cleaning solutions

  • Water

  • Biological fluids

Potential wetted materials include SS316, Hastelloy, special engineering plastics, PEEK, ceramic and zirconia ceramic, with several sealing-material options.

Chemical compatibility should always be checked using the actual fluid concentration and temperature.

6. Noise

A laboratory instrument may operate directly beside the user.

Pump noise can come from:

  • Gear meshing

  • Motor

  • Mounting

  • Tubing

  • Pressure fluctuation

  • Machine enclosure

Selected compact BYMP configurations are specified below approximately 55 dB at 2000 rpm in straight-gear configurations.

Actual system noise must be measured after integration.

7. Suction and Sampling

Sampling systems often require the pump to draw fluid from a small reservoir.

The current BYMP configurations can provide inlet vacuum capability around -0.85 bar, depending on speed and configuration.

The complete suction circuit should be tested because tubing, filter resistance and fluid viscosity all influence actual suction performance.

8. A Practical OEM Selection Process

A useful workflow is:

Flow

↓

Differential Pressure

↓

Fluid and Viscosity

↓

Temperature

↓

Suction

↓

Duty Cycle

↓

Materials

↓

Motor and Controller

↓

Prototype Validation

This is usually more reliable than choosing a pump simply because its catalog flow is close to the required value.

9. EMC and Electrical Integration

The pump motor and controller become part of the instrument's electrical environment.

This matters when the pump operates near:

  • Sensors

  • Measurement circuits

  • Communication interfaces

  • Signal amplifiers

  • Control electronics

EMC should therefore be considered during the prototype stage rather than after mechanical design is complete.

10. Service Life

Selected Boyang micro magnetic gear pump configurations can provide service life exceeding 20,000 hours under appropriate clean-medium conditions.

Actual life depends on:

  • Fluid cleanliness

  • Pressure

  • RPM

  • Temperature

  • Viscosity

  • Dry running

  • Material selection

  • Duty cycle

The service-life figure should therefore be treated as an application-dependent engineering parameter.

FAQ

Which model should I start with for laboratory equipment?

Start with the required flow and pressure. BYMP020 and BYMP030 are useful starting points for smaller fluid circuits, while BYMP060 and larger configurations can be evaluated for higher flow.

Can the pump handle chemical reagents?

Selected material configurations can be evaluated for chemical compatibility.

Can the motor and controller be customized?

Yes. Pump, BLDC motor and control requirements can be evaluated together for OEM systems.

The correct laboratory pump is not necessarily the smallest or highest-pressure model. It is the model that operates at the required point with appropriate materials, noise and control characteristics.