Precision DEF/AdBlue Dosing and Fluid Delivery
In automotive and marine Selective Catalytic Reduction (SCR) systems, the dosing pump must deliver the required amount of DEF/AdBlue reliably under changing operating conditions.
The challenge is not simply flow rate.
The engineer must also consider:
-
DEF concentration
-
Temperature
-
Differential pressure
-
Suction conditions
-
Crystallization risk
-
Materials compatibility
-
Start-stop operation
-
Vibration
-
Noise
-
Long-term sealing reliability
For compact OEM systems, a magnetic-drive micro gear pump can provide positive-displacement flow control while avoiding a conventional rotating shaft seal through the fluid boundary.
1. Why Leakage Matters in DEF Systems
DEF/AdBlue is a water-based urea solution.
If fluid escapes through a dynamic shaft-sealing area and contacts air, water can evaporate and leave urea deposits.
Over time, deposits can interfere with mechanical components and increase maintenance requirements.
A magnetic drive changes the architecture.
The motor transfers torque magnetically through a stationary isolation barrier, keeping the pumped fluid separated from the motor-side drive.
This reduces the leakage path associated with a conventional rotating shaft seal.
2. Positive-Displacement Flow Control
A gear pump moves a relatively defined volume per revolution.
The basic relationship is:
Theoretical Flow = Displacement × RPM
This allows the pump output to be controlled through motor speed.
Actual flow depends on:
-
Differential pressure
-
Fluid properties
-
Temperature
-
RPM
-
Internal leakage
-
Pump configuration
For SCR applications, this makes the pump suitable for controlled fluid delivery where flow needs to respond to operating conditions.
3. Current Boyang Micro Magnetic Gear Pump Range
The current product range is broader than the previous BYMP020–BYMP350 structure.
| Series | Displacement Options | Maximum Listed Flow |
|---|---|---|
| BYMP020 | 0.2 / 0.39 / 0.6 / 0.7 ml/rev | Up to 2.2 L/min |
| BYMP030 | 1.0 / 1.2 / 1.7 / 1.9 ml/rev | Up to 6.0 L/min |
| BYMP060 | 2.4 / 3.5 ml/rev | Up to 10.5 L/min |
| BYMP070 | 4 / 6 / 9 / 12 / 17 ml/rev | Up to 55 L/min |
| BYMP100 | 26 ml/rev | Up to 65 L/min |
An SCR dosing system generally does not need the highest possible flow.
The correct model should be selected according to the required dosing range, pressure, fluid temperature and control strategy.
4. Material Compatibility
DEF applications require careful material selection.
Current BYMP configurations can use combinations of:
-
SS316 / SS316L
-
Hastelloy
-
Engineering plastics
-
Filled PEEK gears
-
Ceramic components
-
Zirconia ceramic shafts
-
FKM
-
EPDM
-
PTFE
-
FVMQ
-
CR
The final wetted-material configuration should be selected based on the actual DEF formulation, temperature and operating environment.
5. Automotive vs. Marine SCR
Automotive and marine systems can have different operating conditions.
Automotive applications may emphasize:
-
Compact installation
-
Frequent start-stop cycles
-
Vibration
-
ECU-controlled dosing
-
Low power consumption
Marine systems may emphasize:
-
Long continuous operation
-
Salt-air environment
-
Vibration
-
Maintenance intervals
-
Larger fluid transfer requirements
The same basic pump architecture may therefore require different motor, material, mounting and control configurations.
6. Suction and Priming
SCR systems may place the pump below or above the DEF reservoir.
The current BYMP configurations can provide inlet vacuum capability around -0.85 bar, depending on speed and configuration.
Suction performance depends on:
-
Tubing length
-
Tubing diameter
-
Fluid temperature
-
DEF viscosity
-
Filter resistance
-
Pump speed
-
Reservoir height
A practical prototype should test the actual suction circuit rather than evaluating the pump alone.
7. Pressure Selection
Engineers should distinguish:
Pump differential pressure
from
System withstand pressure.
Applicable BYMP configurations can provide approximately 20–30 bar differential pressure for water delivery and 25–40 bar system withstand pressure.
These figures are not interchangeable and should not be interpreted as universal DEF operating limits.
The actual DEF operating point should be validated using the specific pump configuration.
8. Marine Installation Considerations
Marine SCR equipment may operate for long periods.
The pump selection should therefore consider:
-
Continuous duty
-
Fluid cleanliness
-
Vibration
-
Mounting
-
Motor cooling
-
Electrical protection
-
Connector sealing
-
Maintenance access
Selected BYMP configurations can be specified for service life exceeding 20,000 hours under appropriate clean-medium conditions.
Actual service life depends on the complete application.
9. Control Options
The BLDC motor can be configured for variable-speed operation.
Depending on the system architecture, control may involve:
-
PWM
-
Analog control
-
Closed-loop speed control
-
CAN
-
External controller
The appropriate control method depends on the vehicle or marine control architecture.
FAQ
Can a magnetic gear pump be used for DEF/AdBlue?
Yes, selected materials and configurations can be evaluated for DEF/AdBlue fluid handling.
Why use magnetic drive?
Magnetic drive transfers torque without requiring a rotating shaft to penetrate the fluid boundary, reducing the dynamic sealing interface.
What flow range is available?
The current Boyang family covers approximately 0.2–26 ml/rev displacement and up to 65 L/min, depending on series and configuration.
Is 40 bar the continuous DEF working pressure?
No. System withstand pressure must not be confused with continuous differential pressure.
For an SCR OEM project, the pump should be selected using the actual DEF flow, differential pressure, temperature, suction conditions and duty cycle.
Products
Brushless Motor
16mm Brushless
24mm Brushless
28mm Brushless
30mm Brushless
57mm Brushless
60mm BLDC
92mm BLDC
150mm BLDC
DC Brush Motor
30mm Brush
36mm Brush
38mm Brush
42mm Brush
52mm Brush
80mm Brush
90mm Brush
Brushless Gear Pump
20 Gear Pump
30 Gear Pump
60 Gear Pump
100 Gear Pump
150 Gear Pump
200 Gear Pump
350 Gear Pump
Brushless Fan/Blower
25 Cross Flow Fan
30 Cross Flow Fan
40 Cross Flow Fan
50 Cross Flow Fan
60 Cross Flow Fan
90 Cross Flow Fan
120 Cross Flow Fan
Servo Motor
40 Servo Motor
60 Servo Motor
80 Servo Motor
110 Servo Motor
130 Servo Motor
180 Servo Motor
Planerary Gearbox
22 Planetary Gear
28 Planetary Gear
32 Planetary Gear
36 Planetary Gear
42 Planetary Gear
60 Planetary Gear
90 Planetary Gear
120 Planetary Gear
Motor Controller
3A Integrated Controller
5A Integrated Controller
8A Integrated Controller
3A BLDC Controller
15A BLDC Controller
50A BLDC Controller
AC BLDC Driver
Panel Driver
Custom Parts
Speed Regulating
Dissipating Housing
Connector
Motor Bracket
Custom Solutions