Free Quote
Leave Your Message
Micro Gear Pumps for Automotive & Marine SCR | DEF/AdBlue Pump
Brushless DC Gear Pumps

Micro Gear Pumps for Automotive & Marine SCR | DEF/AdBlue Pump

2026-09-04

Precision DEF/AdBlue Dosing and Fluid Delivery

In automotive and marine Selective Catalytic Reduction (SCR) systems, the dosing pump must deliver the required amount of DEF/AdBlue reliably under changing operating conditions.

The challenge is not simply flow rate.

The engineer must also consider:

  • DEF concentration

  • Temperature

  • Differential pressure

  • Suction conditions

  • Crystallization risk

  • Materials compatibility

  • Start-stop operation

  • Vibration

  • Noise

  • Long-term sealing reliability

For compact OEM systems, a magnetic-drive micro gear pump can provide positive-displacement flow control while avoiding a conventional rotating shaft seal through the fluid boundary.

1. Why Leakage Matters in DEF Systems

DEF/AdBlue is a water-based urea solution.

If fluid escapes through a dynamic shaft-sealing area and contacts air, water can evaporate and leave urea deposits.

Over time, deposits can interfere with mechanical components and increase maintenance requirements.

A magnetic drive changes the architecture.

The motor transfers torque magnetically through a stationary isolation barrier, keeping the pumped fluid separated from the motor-side drive.

This reduces the leakage path associated with a conventional rotating shaft seal.

2. Positive-Displacement Flow Control

A gear pump moves a relatively defined volume per revolution.

The basic relationship is:

Theoretical Flow = Displacement × RPM

This allows the pump output to be controlled through motor speed.

Actual flow depends on:

  • Differential pressure

  • Fluid properties

  • Temperature

  • RPM

  • Internal leakage

  • Pump configuration

For SCR applications, this makes the pump suitable for controlled fluid delivery where flow needs to respond to operating conditions.

3. Current Boyang Micro Magnetic Gear Pump Range

The current product range is broader than the previous BYMP020–BYMP350 structure.

Series Displacement Options Maximum Listed Flow
BYMP020 0.2 / 0.39 / 0.6 / 0.7 ml/rev Up to 2.2 L/min
BYMP030 1.0 / 1.2 / 1.7 / 1.9 ml/rev Up to 6.0 L/min
BYMP060 2.4 / 3.5 ml/rev Up to 10.5 L/min
BYMP070 4 / 6 / 9 / 12 / 17 ml/rev Up to 55 L/min
BYMP100 26 ml/rev Up to 65 L/min

An SCR dosing system generally does not need the highest possible flow.

The correct model should be selected according to the required dosing range, pressure, fluid temperature and control strategy.

4. Material Compatibility

DEF applications require careful material selection.

Current BYMP configurations can use combinations of:

  • SS316 / SS316L

  • Hastelloy

  • Engineering plastics

  • Filled PEEK gears

  • Ceramic components

  • Zirconia ceramic shafts

  • FKM

  • EPDM

  • PTFE

  • FVMQ

  • CR

The final wetted-material configuration should be selected based on the actual DEF formulation, temperature and operating environment.

5. Automotive vs. Marine SCR

Automotive and marine systems can have different operating conditions.

Automotive applications may emphasize:

  • Compact installation

  • Frequent start-stop cycles

  • Vibration

  • ECU-controlled dosing

  • Low power consumption

Marine systems may emphasize:

  • Long continuous operation

  • Salt-air environment

  • Vibration

  • Maintenance intervals

  • Larger fluid transfer requirements

The same basic pump architecture may therefore require different motor, material, mounting and control configurations.

6. Suction and Priming

SCR systems may place the pump below or above the DEF reservoir.

The current BYMP configurations can provide inlet vacuum capability around -0.85 bar, depending on speed and configuration.

Suction performance depends on:

  • Tubing length

  • Tubing diameter

  • Fluid temperature

  • DEF viscosity

  • Filter resistance

  • Pump speed

  • Reservoir height

A practical prototype should test the actual suction circuit rather than evaluating the pump alone.

7. Pressure Selection

Engineers should distinguish:

Pump differential pressure

from

System withstand pressure.

Applicable BYMP configurations can provide approximately 20–30 bar differential pressure for water delivery and 25–40 bar system withstand pressure.

These figures are not interchangeable and should not be interpreted as universal DEF operating limits.

The actual DEF operating point should be validated using the specific pump configuration.

8. Marine Installation Considerations

Marine SCR equipment may operate for long periods.

The pump selection should therefore consider:

  • Continuous duty

  • Fluid cleanliness

  • Vibration

  • Mounting

  • Motor cooling

  • Electrical protection

  • Connector sealing

  • Maintenance access

Selected BYMP configurations can be specified for service life exceeding 20,000 hours under appropriate clean-medium conditions.

Actual service life depends on the complete application.

9. Control Options

The BLDC motor can be configured for variable-speed operation.

Depending on the system architecture, control may involve:

  • PWM

  • Analog control

  • Closed-loop speed control

  • CAN

  • External controller

The appropriate control method depends on the vehicle or marine control architecture.

FAQ

Can a magnetic gear pump be used for DEF/AdBlue?

Yes, selected materials and configurations can be evaluated for DEF/AdBlue fluid handling.

Why use magnetic drive?

Magnetic drive transfers torque without requiring a rotating shaft to penetrate the fluid boundary, reducing the dynamic sealing interface.

What flow range is available?

The current Boyang family covers approximately 0.2–26 ml/rev displacement and up to 65 L/min, depending on series and configuration.

Is 40 bar the continuous DEF working pressure?

No. System withstand pressure must not be confused with continuous differential pressure.

For an SCR OEM project, the pump should be selected using the actual DEF flow, differential pressure, temperature, suction conditions and duty cycle.