Micro Gear Pumps for Medical & Diagnostic Equipment
Medical and diagnostic instruments often require controlled fluid delivery in a very limited installation space.
Typical applications include:
-
Reagent delivery
-
Sample preparation
-
Buffer circulation
-
Washing and flushing
-
Diagnostic fluid handling
-
Sampling
-
Automated liquid handling
-
Compact cooling circuits
The pump should be selected according to the complete fluid circuit rather than catalog flow alone.
1. Start With the Actual Fluid Circuit
An instrument may contain:
-
Reservoir
-
Filter
-
Tubing
-
Valves
-
Reaction chamber
-
Sampling chamber
-
Waste line
Every component contributes resistance.
Therefore, the pump needs to be evaluated at the actual operating flow and differential pressure.
2. Current BYMP Range
Boyang's current micro magnetic gear pump range includes:
| Series | Displacement Options | Maximum Listed Flow |
|---|---|---|
| BYMP020 | 0.2 / 0.39 / 0.6 / 0.7 ml/rev | Up to 2.2 L/min |
| BYMP030 | 1.0 / 1.2 / 1.7 / 1.9 ml/rev | Up to 6.0 L/min |
| BYMP060 | 2.4 / 3.5 ml/rev | Up to 10.5 L/min |
| BYMP070 | 4 / 6 / 9 / 12 / 17 ml/rev | Up to 55 L/min |
| BYMP100 | 26 ml/rev | Up to 65 L/min |
For medical and analytical instruments, the smaller displacement configurations are often the first models to evaluate.
Higher-flow configurations can be considered when the instrument requires flushing, circulation or rapid fluid transfer.
3. Flow and Speed
Theoretical flow is approximately:
Flow = Displacement × RPM
Actual flow depends on:
-
Differential pressure
-
Viscosity
-
Temperature
-
Pump speed
-
Internal leakage
-
Pump configuration
This means an engineer should specify the required flow at the actual working condition.
4. Low Pulsation and Repeatability
Positive-displacement gear pumps can provide stable fluid delivery when properly selected.
However, actual flow stability depends on:
-
Gear design
-
Pressure
-
Speed
-
Fluid viscosity
-
Pump clearance
-
Motor control
-
Tubing and valve behavior
The complete fluidic circuit should therefore be tested rather than evaluating the pump as an isolated component.
5. Material Selection
Medical and diagnostic applications may involve reagents, cleaning fluids, buffers and other chemicals.
Potential wetted materials include:
-
SS316
-
Hastelloy
-
Special engineering plastics
-
Filled PEEK
-
Ceramic
-
Zirconia ceramic
-
FKM
-
EPDM
-
PTFE
-
FVMQ
-
CR
Material selection should be based on the actual chemical compatibility requirement.
6. Noise
Laboratory and diagnostic equipment is often used close to operators.
Current compact BYMP configurations can provide low-noise operation, with specified BYMP020, BYMP030 and BYMP060 straight-gear configurations below approximately 55 dB at 2000 rpm.
System-level noise still depends on motor, mounting and machine structure.
7. Suction and Sampling
Sampling equipment may place the fluid reservoir below the pump.
In these applications, inlet vacuum performance becomes important.
Current BYMP configurations can provide inlet vacuum capability around -0.85 bar, depending on speed and configuration.
Suction performance should be tested with the actual tubing, filter and fluid.
8. Dry Running During Startup
Some automated instruments may experience short periods of air ingestion during startup or reservoir replacement.
Current BYMP configurations are designed with materials and internal structures suitable for demanding operating conditions, but dry-running duration should always be evaluated for the specific pump, fluid and duty cycle.
Do not assume that a general dry-running statement means unlimited dry operation under every condition.
9. OEM Motor and Controller Integration
For medical and diagnostic equipment, the pump cannot always be evaluated separately from its motor.
The engineer may need:
-
12 VDC or 24 VDC
-
PWM speed control
-
Closed-loop speed control
-
Encoder feedback
-
CAN or RS485
-
Compact wiring
-
Low electromagnetic interference
-
Defined startup behavior
Boyang can evaluate the pump and BLDC motor as an integrated OEM solution.
10. Prototype Validation
A practical validation process is:
Select → Prototype → Test Actual Fluid → Test Pressure → Test Temperature → Check Noise → Check Materials → Confirm Duty Cycle
Water testing is useful for initial mechanical evaluation.
Final validation should use the actual reagent, cleaning solution or working fluid.
FAQ
Which BYMP series is suitable for diagnostic equipment?
Low-flow applications can start with BYMP020 or BYMP030. BYMP060 and larger configurations can be evaluated for higher-flow transfer, flushing or circulation.
Can the pump materials be customized?
Yes. Materials, gears, seals, ports and motor configurations can be evaluated according to the fluid and instrument requirements.
Can the pump operate continuously?
Selected configurations can provide service life exceeding 20,000 hours under appropriate clean-medium conditions. Actual service life depends on the complete application.
Can Boyang supply the motor together with the pump?
Yes. Pump and BLDC motor parameters can be evaluated together for OEM integration.
Products
Brushless Motor
16mm Brushless
24mm Brushless
28mm Brushless
30mm Brushless
57mm Brushless
60mm BLDC
92mm BLDC
150mm BLDC
DC Brush Motor
30mm Brush
36mm Brush
38mm Brush
42mm Brush
52mm Brush
80mm Brush
90mm Brush
Brushless Gear Pump
20 Gear Pump
30 Gear Pump
60 Gear Pump
100 Gear Pump
150 Gear Pump
200 Gear Pump
350 Gear Pump
Brushless Fan/Blower
25 Cross Flow Fan
30 Cross Flow Fan
40 Cross Flow Fan
50 Cross Flow Fan
60 Cross Flow Fan
90 Cross Flow Fan
120 Cross Flow Fan
Servo Motor
40 Servo Motor
60 Servo Motor
80 Servo Motor
110 Servo Motor
130 Servo Motor
180 Servo Motor
Planerary Gearbox
22 Planetary Gear
28 Planetary Gear
32 Planetary Gear
36 Planetary Gear
42 Planetary Gear
60 Planetary Gear
90 Planetary Gear
120 Planetary Gear
Motor Controller
3A Integrated Controller
5A Integrated Controller
8A Integrated Controller
3A BLDC Controller
15A BLDC Controller
50A BLDC Controller
AC BLDC Driver
Panel Driver
Custom Parts
Speed Regulating
Dissipating Housing
Connector
Motor Bracket
Custom Solutions